fraktal-core — Framework Library (Fraktal Core §2.2)

The Fraktal Core base classes, contract types, FB_PermIntlk, the base TcUnit suite, and the test-first scaffold — the “lifecycle written once” of Core §2.2/§6.1. Part I (the platform-neutral normative standard) is Fraktal_Core_Part_I.md; this library is its reference implementation on the TwinCAT 3 binding (Part II, fraktal-tc3).

Core 0.25.0.0 puts retained data behind a project-chosen persistence medium (I_PersistMedium: files in a folder, or a retentive pool): a root’s live station, line and model configuration, its parameter sets and the local user table, restored at start and rewritten after every accepted change (IMPLEMENTATION_NOTES §163; the Press bench keeps them in C:\ProgramData\Fraktal\PressDemo\). Core 0.24.0.0 added the user table outside the symbol table, controller/IPC health from the Beckhoff Device Manager and the EtherCAT master’s own state, frame and CRC counters (§160-§162). The Windows clock adapter observes the target’s existing time service and expires missing quality; see the build and installation guide. Modules 0.11.0.3 pins that Core dependency. The latest source audit is Core and Press TC3 feature gaps.

Baseline (2026-08-02): Core 0.4.0.0 / Modules 0.3.0.0 build clean and their TcUnit gates are green. All three PLC projects returned LastBuildInfo=0 with an empty Error List and regenerated their TMC files, and both isolated-runtime gates pass — 92/92 tests across 28 suites (Core+Modules 84/26, internal Press bench 8/2), repeated on a Windows 10 x64 VM. Summaries, runner identities and artifact SHA-256 hashes are archived in ../../../Specification/Evidence/.

Separately, an earlier snapshot was deployed to a development runtime and exercised end-to-end over TF6100 (Press bench cycling; generic HMI commanding; QUERY_CONFIG config manifest and OPC.UA.DA publication obscuring confirmed). That live result is framework-integration evidence on a development runtime — not a machine acceptance, safety or production claim, and not re-run against this snapshot. See ../../../Specification/Reports/OBJECTIVES_AUDIT.md. Per Core §2 / TC3 §2.1 pin your exact XAE/XAR build; the plcproj files target 4024+ (ABSTRACT FBs/methods). The sources are kept source-compatible with TwinCAT 3.1.4024: no optional/defaulted method inputs (a 4026+ feature) — every method input is passed explicitly at every call site (see IMPLEMENTATION_NOTES.md §62/§64/§69). File an issue for anything a pinned compiler rejects.

Framework/
Fraktal_Core/ the Core library (save/install as a versioned library)
Params/PL_Fraktal.TcGVL framework constants
DUTs/ E_ExecState · E_Reason (§8.8 framework bands) · ST_Diagnostic ·
step/condition/decision records (§6.5, §6.9(b), §6.11) ·
part context (§3.16) · mode/module enums
Interfaces/ I_Module · I_Unit · I_EquipmentModule · I_ControlModule ·
I_RecipeProvider (§3.8) · I_DeviceConnector (§3.15) ·
I_PartCarrier (§3.16) · I_VerdictProvider
PermIntlk/FB_PermIntlk the §7.2 container (Define / SetBypass / ClearBypass / Diagnostic)
BaseClasses/ FB_ControlModuleBase · FB_EquipmentModuleBase · FB_UnitBase
(template method: a type overrides ONLY _M_Dispatch — §2.2;
the Unit base adds modes/cascade, the step chain + stall walk,
and the wired-in cycle profiler §6.2/§6.9/§8.11.4)
Connectivity/ FB_DeviceConnectorBase (§3.15, T7 once) · FB_LocalRecipeProvider (§3.8)
Platform/F_Now [TC3] synchronized-clock read (§2.7)
Platform/F_TimingUpdate §8.11.4 timing aggregate math (pure, unit-tested)
BaseClasses/FB_CycleProfiler §8.11.4 cycle waterfall + per-step stats + time-class split
(WorkTime = real cycle time; fed by _M_SetStep)
Fraktal_Modules/ reusable module library
FraktalCore.tsproj XAE solution for the Core library alone
FraktalModules.tsproj XAE solution for the module library alone
TwinCAT Fraktal.tsproj XAE solution loading both libraries together
Examples/ example applications, one solution folder each
CoreDemo/Fraktal_Demo/ two-root smoke application (§3.1a; sources only,
no .tsproj — add it to a solution to build)
PressDemo/ internal Fraktal feature-testing bench
PressDemo.tsproj the XAE solution (PressDemoX32 = 32-bit variant)
Fraktal_Press_Demo/ simulated test-bench PLC project (not a real project)
PressTests.plcproj the bench's integration gate (own solution)
PressTests/ FB_PressDemoUnit_Tests · FB_FaultRecovery_Tests
_Config/IO/ exported physical I/O configuration
Tests/ the aggregate Core + Modules gate, self-contained
Fraktal_Tests.plcproj its manifest (every Compile path downward)
FraktalTests.tsproj/.slnx its XAE solution (ADS port 851)
Fraktal_Tests/ aggregate TcUnit test sources (§5.7)
FB_ProbeCM / FB_ProbeEM minimal concrete probes for the bases
FB_Base_Tests T1 · T2 · T4 (+ rollup/T6 at base level) proven ONCE
FB_PermIntlk_Tests first-out ordering · bypass rules
FB_Timing_Tests §8.11.4: exact math · classified cycle publication · command rows
PRG_TcUnitRunner TcUnit.RUN() — driven headless by TcUnit-Runner (TC3 §5.7)
tools/ source audits (e.g. Test-OpcUaPublication.ps1)
tools/ this binding's gates and generators. They live here,
beside the sources they check and mirroring
`PLC/Allen-Bradley/tools/`, so a binding carries its
own toolchain and neither can silently drift from it.
plc_lint.py 18 source rules, both build profiles (§1.5/§5.5/§6.8)
ld_rung_gen.py LD rungs by clone or declaration; ld_dump/sfc_dump
read the generated body back as a graph (the gate)
Invoke-TwinCatBuild.ps1 hidden-XAE CheckAllObjects on all five solutions
Invoke-TwinCatLibraryInstall.ps1 save-as-library + install, in dependency order
Invoke-TwinCatTcUnitGate.ps1 / tcunit_to_junit.py runtime gate + result validation
test_*.py their own suites; they import flat, so run them with
`python -m unittest discover -s <this dir> -t <this dir>`
(cross-tree gates stay in the repository-root `tools/`)
scaffold/FB_TemplateCM/ "new CM type in 30 minutes" — pre-wired, initially RED (§5.7)
IMPLEMENTATION_NOTES.md every reconciliation vs. the drafts + proposed Core §3.2 amendments

The authoritative interaction and evidence procedure is ../../../Specification/Guides/TWINCAT_XAE_WORKFLOW.md. It records the exact Core→Modules save/install order, nested-build versus CheckAllObjects boundary, hidden-XAE automation, isolated-runtime download/run sequence, and the 2026-08-01/02 execution history.

A .plcproj is not opened directly like a solution — it is added into a TwinCAT XAE project. Verified on TwinCAT 3.1 4024.x (TcXaeShell): create/open a TwinCAT solution, then right-click the PLC node → Add Existing Item… → select the .plcproj. x32 vs x64 XAE does not matter for compiling; it only selects which local runtime (TwinCAT System Service) the shell pairs with. 4024.75 is fine — 4024+ is required (ABSTRACT FBs/methods).

  1. Open the dedicated 4026 wrapper Framework/FraktalCore.slnx, or in TcXaeShell create a TwinCAT XAE Project and add Framework/Fraktal_Core/Fraktal_Core.plcproj beneath its PLC node. The referenced Beckhoff libraries (Tc2_Standard, Tc2_System, Tc2_Utilities, Tc3_Module) resolve from the local repository automatically (they are placeholder references, * version).
  2. Build warning-clean (Core §2), then Save as library and install; consumers pin the version (§2.2/§5.4). If the compiler rejects a construct, check the watch-item list in IMPLEMENTATION_NOTES.md §8 — these are known first-compile candidates, fix at source.
  3. Close the Core wrapper, then open Framework/FraktalModules.slnx, or add Framework/Fraktal_Modules/Fraktal_Modules.plcproj to another otherwise-empty XAE solution. It references the installed Fraktal_Core; build it, then save/install it as a library. It deliberately has no task or MAIN.
  4. Add either executable fixture: Examples/CoreDemo/Fraktal_Demo/Fraktal_Demo.plcproj, or Examples/PressDemo/Fraktal_Press_Demo/Fraktal_Press_Demo.plcproj for the pneumatic press. The ready-made 4026 system project is Examples/PressDemo/PressDemo.slnx (PressDemo.tsproj); PressDemoX32.sln is the legacy XAE-shell wrapper. Open one wrapper only—both point at the same Press PLC source project. For the VS2017-based x32 Shell, use Framework/FraktalCore.sln, then Framework/FraktalModules.sln for library preparation: .slnx is a modern IDE format. Save/install updated exports under Framework/Release/x32 and reopen Press before compiling. The x32 IDE supports x86 and x64 PLC targets; select the PLC’s target architecture. See the workflow guide §4.0 for the matching 32-bit PowerShell automation. If a consumer reports unknown Core types or missing base classes inside Fraktal_Modules, check the Modules library’s own Fraktal_Core reference. Adding Core directly to the application cannot repair an installed Modules library that omitted its dependency. Restore the reference, save/install the libraries in dependency order, then reopen the consumer to reload its graph.
  5. Open the dedicated Tests/FraktalTests.slnx, or create a separate XAE solution and add Tests/Fraktal_Tests.plcproj; install TcUnit (tcunit.org) first. Then run the press gate too: Examples/PressDemo/PressTests.slnx. Never load PressTests beside the Press Demo project: it links the exact Press source objects and duplicate GUIDs make TwinCAT rewrite those files. Each PlcTask.TcTTO calls its runner. Run only on an isolated test runtime/ADS port and leave Autostart Boot Project disabled. Start it deliberately, harvest the result, and stop it; never make it the machine boot application. All suites green is the M1 acceptance bar.
  6. Wire TcUnit-Runner into CI so the JUnit results gate the merge alongside lint (Core §6.8, §1.5).

A chain is a chain: it extends FB_SequenceBase, records steps with M_Step, and progresses through the shared result _retVal. Only who evaluates the transition differs, and everything else follows from that one fact.

ST SFC LD (integer state machine)
Owns the transition M_Advance the SFC runtime the rungs
Body of the POU CASE _step OF the chart rungs gated on _step
Step body lives in a CASE branch an ACTION an ACTION
Calls M_Advance? yes, ends every branch no yes, from the action
Transition condition (inside M_Advance) _retVal = E_StepResult.ADVANCE (inside M_Advance)
A jump is OnJump1 := <step> a branch whose condition is _retVal = E_StepResult.JUMP1 OnJump1 := <step>
Clears _retVal M_Advance, on commit FB_UnitBase per scan M_Advance, on commit
Overrides M_ChainRun? yes (that is the body) no — its body is the chart yes

The per-scan clear is never a project’s job: a chain registers itself in M_Attach and FB_UnitBase._M_BeginSequenceScan resets every attached chain before _M_Dispatch runs (§1.1 O1). An SFC chart needs no wiring at all to be safe against a stale ADVANCE.

Fraktal_Press_Demo ships the AUTO chain in ST (FB_PressDemoAuto) and SFC (FB_SFC_PressDemoAuto) so the two can be compared side by side. The FB_SFC_ prefix is not a naming convention — it exists only so two renditions of one chain can coexist in one project. A real project has one chain per mode and names it FB_<Thing><Mode>.

The chart graph is drawn in XAE. A .TcPOU SFC body is a serialized object graph (SFCImplementationObject → SFCSegment → SFCElementList), and synthesising one by hand is not worth attempting — a malformed archive is worse than none because it still looks like a finished file. Draw the steps and transitions; the rest is mechanical and can be scripted.

  1. Write the step bodies as ACTIONS. MainAction resolves to an action of the POU, never a method. Each action is the ST branch minus its M_Advance call: an action only produces _retVal.
  2. Name a step N<StepNo>, and its action A<StepNo>_<What>. The step carries the same number the step record publishes (M_Step(StepNo := 200) → step N200 → row N200 on the §3.13 chart → 200: in the ST twin), so one step number reads identically in the chart, the code, the operator’s flow chart and a stall message. The action keeps the A prefix precisely so the two never blur: in the archive a step and its MainAction are different objects, and N200 bound to A200_RamDown says which is which at a glance. A step’s “wait at the join” placeholder follows the same rule (N250 → _aN250_active).
  3. Every transition is _retVal = E_StepResult.ADVANCE, except a jump branch, which is _retVal = E_StepResult.JUMP1 (JUMP2/JUMP3 for further branches).
  4. Bind each step’s MainAction. The attribute is {700a583f-b4d4-43e4-8c14-629c7cd3bec8}.
  5. Use the inherited native Reset flag. In the chart SFC settings, disable defaults and enable Reset with Use=true, Declare=false. FB_SequenceBase owns SFCReset: M_Restart/M_ChainReset request the graph reset, and the initial action’s mandatory M_Step consumes it. Do not redeclare the flag or add a project reset call. Resetting only _step cannot restart a native graph.

Read the archive’s own descriptor table; never guess an attribute. Each step carries ten attributes and five of them are empty strings. The archive maps every GUID to an identifier and a description, so the binding target is a lookup, not an inference:

Attribute GUID
Name {38391c6d-6d4a-42f8-8ee7-9f45e5adafa8}
Comment {7d894980-aeea-405c-a0f6-e2b26429c58f}
Exclude {01580b27-6378-448b-8ecb-0e4b795b58d6}
InitStep {6844a48e-46c2-4cc8-a185-a478f3b99cc0}
Duplication {62e1754b-7629-4e63-9cec-10ae0c536f1f}
MinTime {cacf1a68-236e-47c2-b7b1-1cf9199718cb}
MaxTime {b693554c-1b01-4a8d-afde-9e3a46f7465d}
MainAction {700a583f-b4d4-43e4-8c14-629c7cd3bec8}
EntryAction {a6b08bd8-b696-47e3-9cbf-7408b61c9ff8}
ExitAction {a2621e18-7de3-4ea6-ae6d-89e9e0b7befd}

MainAction, not EntryAction. Step bodies poll child Done flags and timers, so they must run every scan the step is active. An entry action runs once on activation, and a chain wired that way stalls at its first step forever — which reads as a hung machine, not a wiring mistake.

Two work positions that run at the same time and independently. There are two forms; prefer the first unless the chart itself is the clearest documentation.

Sub-chain fork — every language, including ST. Each leg is an ordinary chain, so it brings its own step pointer, transition result and step-scoped latches, and nothing about it has to know it runs beside another. One step forks and joins:

500: M_Step(StepNo := 500, StepName := 'project.step.bothPositions', Awaits := 0,
AwaitingLabel := '', TimeClass := E_TimeClass.WORK, ExpectedTime := T#0S);
M_RunPar(Chain := _positionA, BaseStepNo := 600, Branch := 1);
M_RunPar(Chain := _positionB, BaseStepNo := 700, Branch := 2);
_retVal := M_ParJoin();
M_Advance(OnAdvance := 999);

M_ParJoin commits only when every leg run that scan reports Done. The leg list is the calls themselves — nothing to register, nothing to forget when a leg is added. Worked example: FB_ProbeParChain / FB_ProbeLeg / FB_SequencePar_Tests.

Native divergence — drawn in the chart. In XAE, select the transition after the forking step and insert a parallel branch. In the archive the two shapes are told apart by what each leg starts with:

leg starts with meaning
SFCBranch whose legs open with SFCTransition a transition alternative (one leg runs)
SFCBranch whose legs open with SFCStep a step parallel (all legs run)

Rules for a natively drawn leg:

  1. Every leg step names its leg on its own step record: Branch := 1 as the last argument of M_Step. That is what keeps this leg’s issue latch, delay and message separate from the main line’s, so both can command their own children in the same scan. Main-line steps omit it — it defaults to this chain’s own leg, so a leg written as a sub-chain never mentions a branch either. (Under the legacy FRAKTAL_TC3_4024 profile there are no defaulted method inputs, so a 4024 build writes Branch := 0 at every M_Step, as it already does for M_Advance.)
  2. A leg’s transitions read _conRetVal[n], not _retVal. The main line keeps _retVal. Both are cleared once per scan by the base.
  3. Every leg needs a terminal step to wait in. A parallel branch joins only when all legs have reached their last step, so the main line needs one too — that is what A250/A310 are in FB_SFC_PressDemoAuto.
  4. The join transition reads every result, e.g. _retVal = E_StepResult.ADVANCE AND _conRetVal[1] = E_StepResult.ADVANCE.
  5. Number every leg; none is “the main line”. A two-leg fork uses legs 1 and 2. Leaving one on branch 0 makes the chart draw it unindented, as if the other leg were subordinate, and leaves _retVal meaning one thing inside the fork and another outside it. _retVal is the line before and after; between them there are only legs.
  6. A composite step inherits its leg. M_RunSub takes no branch argument — the sub-chain runs on whatever leg the calling step is on, because M_Step already set that. Press AUTO A240 runs the load-position chain from leg 1 and its four steps publish as leg 1.
  7. The fork sits on a chain’s main line. Nest by making a leg a sub-chain instead — that form nests without limit.

A ladder chain is an integer state machine: one rung per state, dispatched on the inherited _step, and the rung writes the next state itself. FB_LD_PressDemoAuto is the worked example; it extends FB_SequenceBase, the same base an ST or SFC chain uses.

Use EN/ENO, not a Run facade. A ladder box only executes on power flow, and XAE already supplies that for any method box: enable EN and the box gains an EN input and an ENO output. The base method is called directly —

BOX "M_Step" params=['EN', 'StepNo', …] returns=['ENO'] EN=true
BOX "M_StepLd" params=['Run','StepNo', …] returns=[] EN=false

— so M_Step, M_Await, M_RunSub and every method on every developer-written FB are callable from a rung with no library change at all. This is the only approach that scales: a project may define or extend module types freely, and adding a hand-written …Ld twin per method per type does not.

FB_SequenceBaseLd has been deleted. Its 27 Run : BOOL facades were reinventing EN. They existed because adding an input to an override is C0094: Interface of overridden method doesn't match declaration, which forced the distinct Ld names — but EN/ENO adds no parameter, so the signature never changes, so no facade and no renaming was ever needed. A ladder chain now extends FB_SequenceBase, exactly like an ST or SFC chain; FB_LD_PressDemoAuto is the worked example. convert_ld_boxes() in tools/ld_rung_gen.py performed the migration and is kept for any chain still carrying the old form.

Removing a type from a released library is a breaking change. Core’s version was not stepped for it because no shipped chain outside this repo consumed the facade; a downstream project that did must migrate with convert_ld_boxes() before resolving Core again.

Two consequences worth knowing before editing an EN-gated box:

  • A value-returning box has TWO outputs: ENO first, then the return value. M_Await reports returns=['ENO','M_Await']. Wiring the result into slot 0 puts it on ENO and leaves the real output dangling; wiring the wrong variable into slot 1 compiles clean and silently strands the intended one. That is a defect no gate catches — see the _partReady/_airReady trap below.
  • EN := FALSE means the box is not executed at all, so its output variable keeps its previous value. A Run := FALSE facade call still ran and wrote its fail-closed default. Inside a rung gated on EQ(_step, N) the two are equivalent, because the variable is only read by that same rung — but a value read outside the rung differs.

The two rung shapes. Everything in a chain is one of these.

Pure logic (initialise, wait on conditions, complete):

[EQ(_step, 100)]──┬──[M_StepLd StepNo:=100, StepName:='…', Awaits:=0,
│ AwaitingLabel:='', TimeClass:=…, ExpectedTime:=…, Branch:=0]
├──[_partReady := M_AwaitLd(Idx:=1,
│ Label:='project.condition.partPresent',
│ Ok:=sensor.OutImm.Value AND sensor.OutImm.Quality)]
├──[_airReady := M_AwaitLd(Idx:=2, Label:='…', Ok:=…)]
├──[_twoHandReady := M_AwaitLd(Idx:=3, Label:='…', Ok:=…)]
├──[_startReady := NOT requireTwoHand OR _twoHandReady]
└──[_partReady AND _airReady AND _startReady]──[MOVE 110 → _step]

Commanding a child (most steps — this is the N110 shape):

[EQ(_step, 110)]──┬──[M_StepLd StepNo:=110, …, Awaits:=_pressRam,
│ AwaitingLabel:='PressRam.RETRACT']
├──[M_TryIssueLd Steppable:=TRUE]──┬──[_pressRam.Command := E_CylinderCommand.RETRACT]
│ ├──[_pressRam.Abort := FALSE]
│ └──[_pressRam.Execute := TRUE]
└──[_pressRam.Done]────────────────┬──[_pressRam.Execute := FALSE]
└──[MOVE 130 → _step]

A jump is not a special construct: it is a second MOVE under a different contact in the same rung (_pressRam.Error → MOVE 210 → _step beside Done → MOVE 220). A terminal step calls M_Complete()/sets Done and does not MOVE.

Never nest a value-returning facade box. Assign each M_AwaitLd, M_PartReceivedLd, decision, or other value-returning call to a declared variable of the exact return type, then combine those variables in a separate logic box. Run is the box’s rung-power/execute input; it is not an accumulator for the previous call’s Boolean result. Every active named wait must execute independently on every scan so the complete diagnostic set remains published.

Why this is a hard rule: XAE lowers a nested graphical output to a temporary named ImpVar<BoxId>_<output ordinal>. In the broken N100 archive, ImpVar597_1 is the return of M_AwaitLd box ID 597 feeding OR box 612, and ImpVar616_1 is the return of M_AwaitLd box ID 616 feeding the Run pin of outer M_AwaitLd box 614. TwinCAT could not type those nested method temporaries. The names were editor-generated, but they were not opaque: their box IDs locate the offending nodes in <NWL><XmlArchive>. Flattening the calls also restores the ST/SFC semantics—three independent result assignments followed by one combined transition.

Rules that differ from ST.

  1. M_TryIssueLd is what re-arms per step — the issue latch is cleared by M_Step on a step-number change (a chart language never reaches M_ClearTransition).
  2. No M_Advance, no _retVal. The rung writes _step directly; that is the idiomatic ladder transition and rule S1 accepts it (it requires a step record plus some way to move, not a nominated one).
  3. Drop the child’s Execute in the same rung that leaves the step — §6.1’s Execute-drop reset is what returns the child to READY.

Do not synthesise the body from nothing. A <NWL> network is a serialized object graph of BoxTreeBox/BoxTreeOperand/BoxTreeDemux/BoxTreeAssign nodes with Id identities and VarId power-rail nodes — roughly 40 kB per rung. Hand-writing one is not viable and cutting nodes with a regex has produced a file that stayed plausible while ceasing to be well-formed XML. What is viable is cloning a rung that already compiles — see the next section. After any edit, verify with CheckAllObjects (see Specification/Guides/TWINCAT_XAE_WORKFLOW.md) — the press demo resolves only once Core and Modules are installed as libraries.

Generating a rung by cloning a worked example

Section titled “Generating a rung by cloning a worked example”

tools/ld_rung_gen.py generates rungs; tools/test_ld_rung_gen.py is its gate. The method is deliberately narrow, and the narrowness is what makes it safe:

  1. Split, never parse. The archive carries xml:space="preserve", so an ElementTree round-trip rewrites indentation that is real content. split_networks scans <o> depth and returns the raw blocks plus the separator between them — rejoining without it yields </o><o> on one line, which is still valid XML and therefore fails silently.
  2. Clone a rung of the shape you want and renumber every Id/VarId into a fresh range above the file’s maximum. A duplicated Id does not fail to parse; it silently shadows a node.
  3. Rewrite only leaf operands. subst() matches the Operand+Type pair, so a short name cannot match inside a longer one and the type can never drift away from the value — that mismatch is exactly Cannot convert type 'BOOL' to type 'E_VERDICT'. subst_string() additionally derives STRING(INT#n) from the new literal, so a renamed step cannot keep the previous name’s declared length.
  4. Every substitution asserts its hit count. A rewrite that matches nothing reports success and changes nothing; subst() raises instead. _pressRam.Execute occurs twice in a command rung (Set coil and Reset coil) — asserting count=1 there is a bug the assertion catches.
  5. Fix BranchCounter. It is the archive’s monotonic VarId allocator; leaving it below a VarId that now exists lets XAE hand out a duplicate the next time someone opens the chart.
  6. Compile after every rung. ImpVar<BoxId>_<n> in an error message maps directly to that node’s <v n="Id">…L</v>, which locates the fault in seconds — but only if you know which rung you just added.

Worked example — the whole of N130 is N110 with nine operand substitutions:

rung, next_id, next_var = clone(template_N110, id_base=…, var_base=…)
rung.subst("130", "150", count=1) # MOVE target FIRST: doing the gate first
rung.subst("110", "130", count=1) # would collide with the template's MOVE
rung.subst_string("project.step.pressRamUp", "project.step.pressDoorOpen")
rung.subst_string("PressRam.RETRACT", "Door.RETRACT")
rung.subst("_pressRam", "_door", count=1) # the Awaits operand
rung.subst("_pressRam.Command", "_door.Command", count=1)
rung.subst("_pressRam.Abort", "_door.Abort", count=1)
rung.subst("_pressRam.Execute", "_door.Execute", count=2)
rung.subst("_pressRam.Done", "_door.Done", count=1)

Cloning had one hard limit — it can only produce box types that already exist somewhere in the file — so every rung needing M_Delay, M_AskDecision, M_RunSub, M_RaiseWarning, M_ReportFromChild or a child method such as WithdrawOutputs used to stall on “draw one in XAE first”. That limit is gone; see the next section. Cloning is still the shorter route when a rung of the shape you want already exists.

A BoxTreeBox is fully determined by the declaration of the method it calls, so nothing about it has to be copied from anywhere:

Archive field Comes from
InputParam.Names EN, then the VAR_INPUT names in declaration order
InputParam.Types BOOL, then their types
OutputParam ENO : BOOL, then — only if the method returns a value — the method’s own name and return type
OutputItems <n /> when void; otherwise an empty ENO slot then the return slot
CallType / EN / ENO Method / true / true

A method on another FB folds the instance into the box type (method("_pressRam.WithdrawOutputs", …)). The operator boxes, the power rails and the coils are equally mechanical, so tools/ld_rung_gen.py provides a small node algebra and a whole rung is written down:

alloc = Allocator.above(source) # Ids above everything in the file
rail = Rail(alloc.take_var())
items = [
Wire(rail.var_id, compare("EQ", Term(), Value("_step", "INT"),
Value("215", "INT"))),
method("M_Step", rail, [("StepNo", "INT", Value("215", "INT")), …]),
method("M_PartProcessed", rail,
[("Verdict", "E_Verdict", Value("E_Verdict.NOK", "E_VERDICT")), …],
returns=("M_PartProcessed", "BOOL"), result="_partProcessed"),
Coil("_partDispositioned", rail, SET), # (S)
Coil("_partInMachine", rail, RESET), # (R)
move(rail, Value("240", "INT"), "_step", "INT"),
]
text = network(items, alloc, comment="N215")
  • Term() is the left power rail; Wire/Rail are a branch point and its taps, and a rung can only branch through them — power flow in the nested EN form is the nesting.
  • Contact and Value are deliberately different types. Both serialize as BoxTreeOperand, but XAE marks a contact Boolean/Fixed and a plain BOOL argument (Steppable := TRUE) not, so the type alone cannot tell them apart — and in ladder they are not the same thing. Contact(x, negated=True) is --|/|--.
  • Coil(x, rail, RESET) is what x := FALSE means inside an active step. A plain coil driven from the step’s own rail would write TRUE.
  • result= on a value-returning method() is what makes the ENO trap unrepresentable: the return can only land in slot 1.

The gate for all of it is tools/test_ld_rung_gen.py, which regenerates N999 — a rung drawn by hand in the XAE editor — from a declaration and compares it against the real one node for node, pin for pin and flag for flag. If the emitter can reproduce what the editor wrote, a rung it emits for a box with no instance to clone is trustworthy for the same reason.

Dump the result. A clean compile does not prove a generated node exists.

python tools/ld_dump.py <file.TcPOU> # every network, as a graph
python tools/sfc_dump.py <file.TcPOU> # the same for a chart

This is not a convenience, it is the verification step. Two failures it catches that nothing else does:

  • an untyped <o> — a node lifted out of a <l2 … cet="BoxTreeBox"> list loses the type the list gave it collectively. It parses, it compiles, and the box is simply not there. (network() writes NetworkItems with no cet so every item states its own type.)
  • a dead gate. N215 and N230 both compiled while reading EQ(215, 0) and EQ(230, 0) — the step number compared against a leftover constant instead of against _step. Legal IEC, constantly FALSE, no warning from anything.

Rung order is execution order, and it matters. A forward transition re-enters any rung below it in the same scan, because the MOVE writes _step before those rungs are evaluated. That is normally harmless — the chain simply advances a scan earlier than the ST twin would — but not when the two rungs command the same child: §6.1’s Execute-drop reset needs one scan with Execute low, and a Reset coil followed by a Set coil in the same scan never gives it one. The press AUTO chain has two such pairs, and in each the later rung is placed deliberately above the earlier one: the abort at N180 and the reopen at N185 both drive the door, so N185 sits above N180; and N200 extends the ram while N240’s load-position sub-chain retracts it, so N240 sits above N200. The second pair was missed until 2026-09-27: with a zero dwell, N200..N240 ran in one scan, the retract’s Set coil landed in the same scan as the extend’s Reset, the ram kept reporting the extend’s Done, and the cycle finished with the ram still down. Everything else is in step order.

An <SFC> body is a different archive from <NWL>, and simpler. The skeleton is

SFCImplementationObject
└── o n="Root" t="SFCSegment"
└── o n="ElementList" t="SFCElementList"
└── l2 n="InnerList" ← the chart, in order
├── o t="SFCStep" ← EmbeddedMain/Entry/ExitAction, nested
│ ElementList, and l2 n="Attributes"
├── o t="SFCTransition"
├── o t="SFCJump"
└── o t="SFCBranch" ← l2 of SFCSegment legs

Everything meaningful is a GUID-keyed attribute, and the archive ships its own descriptor table — <d2 n="Attributes" ckt="Guid" cvt="SFCAttributeDescription"> maps each GUID to an Identifier. Read it from the file rather than trusting this list; these are the 14 it currently defines:

Identifier GUID Notes
Name 38391c6d-6d4a-42f8-8ee7-9f45e5adafa8 step name (N200); on a transition this holds the CONDITION expression
MainAction 700a583f-b4d4-43e4-8c14-629c7cd3bec8 action run while the step is active
EntryAction a6b08bd8-b696-47e3-9cbf-7408b61c9ff8 runs once on activation
ExitAction a2621e18-7de3-4ea6-ae6d-89e9e0b7befd runs once on deactivation
InitStep 6844a48e-46c2-4cc8-a185-a478f3b99cc0 exactly one step per chart
Parallel 23bdaa98-72ec-41f7-817b-9dede5697086 on a branch: parallel vs alternative
Qualifier e174fc0d-80b0-4a9e-a530-ca239c249a50 action association qualifier
MinTime / MaxTime cacf1a68-… / b693554c-… step active-time bounds
Monitoring 8294df19-5962-4dee-a874-1051dabb0e3e transition monitoring
Comment 7d894980-aeea-405c-a0f6-e2b26429c58f
Duplication 62e1754b-7629-4e63-9cec-10ae0c536f1f copy implementation vs reference
Symbol bc882c11-1e91-4dd8-a6b8-2075724ed18b EnumValue, not a string
Exclude 01580b27-6378-448b-8ecb-0e4b795b58d6 hidden; excludes from build

A real step carries ten of these — Name, Comment, Exclude, InitStep, Duplication, MinTime, MaxTime, MainAction, EntryAction, ExitAction — and four are normally empty strings. A transition carries only Name, Comment, Exclude. Values are typed wrappers: StringValue, BoolValue, or EnumValue (which carries a TemplateGuid before its Value, so a regex written for the string form silently skips it).

Two traps that cost real time:

  • MainAction vs EntryAction. Putting the body on EntryAction runs it once and the chart stalls at its first step forever. MainAction is the one you want.
  • The action is a separate POU object. <Action Name="A200_RamDown"> is a sibling of <Method> under <POU>; the step attribute only holds its name as a string, so a renamed action and a step still naming the old one both parse and neither warns.

Fraktal’s naming makes the step number the same token everywhere: step N<StepNo>, action A<StepNo>_<What> (N200 → A200_RamDown), matching the ST twin’s CASE label and the §3.13 row. The differing prefix is what keeps a step distinguishable from its action object inside the archive.

Because steps and transitions are flat attribute records rather than a wired graph, an SFC chart is materially easier to clone than a ladder rung — retargeting a step is two StringValue edits (Name, MainAction) with no Id/VarId renumbering and no power rails. The same discipline still applies: assert every substitution’s hit count, keep Id/IdParent consistent, and compile after each step.

Reading an archive is far easier than writing one: dump a body’s structure before touching it (python tools/sfc_dump.py <file>, python tools/ld_dump.py <file>). Note that the descriptor <d2> is a dictionary — alternating <v> key and <o> value children, and the values are typed collectively by cvt, so none of them carries a t=. A dumper that filtered on t="SFCAttributeDescription" printed an empty table and an empty chart, and looked like a file with nothing in it. The <NWL> node grammar ld_dump prints is

DEMUX var=N (DEF) ← defines a power node; its <o n="Input"> is what drives it
DEMUX var=N (ref) ← every later use of that same rail
OPERAND "x" : "T" ← Flags 1 = negated contact, 0 = plain
ASSIGN -> "x"{flags=N} ← 2 = Set coil (S), 3 = Reset coil (R), 0 = plain
BOX "M_Step" params=[EN, StepNo, …] ← InputItems positionally match params
  • A .TcPOU edit must target one CDATA section. A method’s declaration and implementation are separate CDATA blocks. A replacement written against the two concatenated matches nothing and reports success — a silent no-op. This bit M_Reset twice.

  • _retVal is a one-scan signal. In a chart the runtime evaluates the transition after the step action, so the value must survive the scan and be gone before the next one. The framework does this; do not add a manual clear.

  • A chart POU must not override M_ChainRun. Its body is the chart. Only a chain used as a composite sub-step (M_RunSub) overrides it, and such a sub-chain must therefore be ST.

  • FUNCTION_BLOCK INTERNAL FB_X EXTENDS FB_Y is legal; any combination of ABSTRACT/FINAL/INTERNAL/PUBLIC/PRIVATE/PROTECTED may precede the name.

  • IEC standard function names are reserved as identifiers — SUB, ADD, DIV, LEN, SEL and the rest. A method input named Sub parses as the subtraction operator and yields ~40 cascading errors on innocent lines. Rule C2 now rejects them; a qualified enum member (E_CylinderPosition.MID) is still fine.

  • M_TryIssue used to fire once per chart RUN in SFC/LD. A chart language never calls M_ClearTransition — its engine owns the transition, so there is no commit point to hang it on — and nothing else re-armed the issue latch. The re-arm now lives in M_Step, the one call every step of every language makes. If you are reading an older chart that only ever commanded its first child, this was why.

  • A parallel leg is not a place to fault quietly. CurrentStep, the §6.9 stall walk and the profiler follow the main line only: a first-out has to name one step. A leg is timed and guarded on its own §3.13 row instead, and a leg that must fault does it through §6.9(d), which stops the whole chain — one leg failing is a failure of the step.

  • Owning a child’s failure is not the same as hiding it. A step that drops Awaits to disposition the failure itself (below) is one case; a step whose command sits behind an IF/CASE is the other, and that one has no rollup at all. Raise it explicitly (Core §6.9(d)):

    IF M_RaiseFromChild(Source := _gauge) THEN
    _gauge.Execute := FALSE; // §6.1 drop-reset frees the child to recover
    RETURN;
    END_IF

    M_RaiseCustom does the same for a condition no module reports — an application rule, an out-of-band measurement — with the step choosing the text, severity, category and drill-down link. Both stop the chain on the step, mark that row of the §3.13 flow chart, and re-arm the step’s latches when the error clears, so the command is re-issued and re-tested rather than resumed mid-handshake. Both are one call in ST, an action line in SFC, and a power-flow-gated box in LD. Worked example: FB_ProbeRaiseChain.

  • Do not fault a condition the step already handles. M_RaiseWarning (a rule the step states) and M_ReportFromChild (a child’s first-out, published but not adopted) record the occurrence and leave the chain running — press AUTO N180 and N200. They are AUTO_RESET come+gone events, so they can never block the next Start, and the base emits each once per step visit so an unguarded call in a step body is correct. Reach for the raising pair only when the machine must stop.

  • Owning a child’s failure means not awaiting it. An awaited child fault is adopted by FB_UnitBase.OnCyclic — _exec := ERROR, _step := 0 — before _M_Dispatch runs, so a chart can never jump on it. A step that wants to disposition the failure itself passes Awaits := 0 and names the wait with M_Await instead (N200 in the press AUTO chain does exactly this).

Rule S1 knows the difference: for an <SFC>/<LD>/<FBD> body it requires the chart contract (_retVal, M_Step() rather than the ST skeleton, so a correct chart is not forced to pretend it is ST.

Building an LD chain (integer-based state machine)

Section titled “Building an LD chain (integer-based state machine)”

This section used to describe a second, incompatible ladder form: a FB_SequenceBaseLd base whose methods took Run : BOOL, and rungs that ended in M_Advance with an OnJump1..3 mapping. Neither is how the ladder works. The facade has been deleted (EN/ENO replaces it) and a rung has always written _step directly. The authoritative description is § “Writing a Ladder sequence rung by rung” above; this heading is kept only so an old link still lands somewhere truthful.

Rule S1 knows the difference between the three faces: an <SFC> chart must not need M_Advance, a <NWL>/<LADDER> chain must carry some way to move (writing _step counts), and an ST chain needs the full CASE _step OF skeleton.

Two TcUnit gates, and why they are separate

Section titled “Two TcUnit gates, and why they are separate”

There are two test projects and you must run both:

Gate Covers Solution
Tests/Fraktal_Tests.plcproj Core + Modules (30 suites / 98 tests, simulated HAL) Tests/FraktalTests.slnx
Examples/PressDemo/PressTests.plcproj Internal Press feature bench (2 suites / 8 integration tests: FB_PressDemoUnit_Tests, FB_FaultRecovery_Tests) Examples/PressDemo/PressTests.slnx

Accept a runtime result only when both its count and runner identity match the selected gate: Core/Modules output is rooted at PRG_TcUnitRunner and reports 98 tests/30 suites; Press output is rooted at PRG_PressTestRunner and reports 8 tests/2 suites. If a Press attempt reports the Core identity, either the wrong solution was downloaded or a previously created Core boot project restarted on that target. Source BootProjectAutostart="false" prevents creating a new autostart configuration; it does not erase boot data that already exists on a runtime.

They are split because of a hard TwinCAT constraint: PLC Control inspects a raw Compile Include path before it evaluates <Link> metadata, so a path containing .. makes the importer try to create a project-tree folder literally named .. and stop with “‘..’ is not a valid folder name.” Every Compile path must run downward from its manifest.

A single aggregate would therefore have to sit at TwinCAT/ to reach both Tests/ and Examples/ — cluttering the root that holds the platform’s projects. Keeping each manifest beside the sources it owns is what lets Tests/ stay self-contained. The press suites still link the same physical objects that deploy (Fraktal_Press_Demo/01_PneumaticPress/...), never copies.

Two rules keep this working, both enforced by plc_lint.py P1:

  • no .. in any Compile path, and every include must resolve;
  • a <Folder Include> list mirrors the Include directories, never the <Link> paths — XAE materialises those entries as real directories on disk, so a mismatch litters the tree with phantom empty folders.

Never load PressTests in the same solution as Fraktal_Press_Demo: both link the same source objects and duplicate in-solution GUIDs make PLC Control rewrite the shared files.

For a compiler-only local/CI check that does not activate or download a target, run tools/Invoke-TwinCatBuild.ps1 (paths below are relative to this directory) from the repository root. It opens each test solution in a separate hidden XAE host, selects x64, asserts Autostart Boot Project is false, and runs the nested IEC project’s CheckAllObjects. Runtime CI supplies the separate isolated-target hook and validates its raw TcUnit summaries with tools/tcunit_to_junit.py, including expected runner identity as well as counts.

Build order matters: save/install Fraktal_Core, then save/install Fraktal_Modules. Fraktal_Demo, Fraktal_Press_Demo, PressTests, and Fraktal_Tests are executable applications, not libraries; Tests additionally needs Fraktal_Modules and TcUnit installed.

Each manifest sits with the sources it owns, so every compile input is a downward path. Keep it that way: do not reintroduce escaping .. compile paths, and do not merge the two gates back into one manifest — that would force it up to TwinCAT/.

If a test runtime is accidentally saved as a boot project and reports a PLC stack overflow during TwinCAT startup, keep outputs safe, return TwinCAT to Config mode, remove/disable the Fraktal_Tests boot project for that ADS port, and restart. The following PREOP→OP / ADS 1804 messages are consequences of the crashed PLC runtime, not separate I/O mapping faults.

Commissioning gates (first power-up of a real machine)

Section titled “Commissioning gates (first power-up of a real machine)”

Two gates in the VAR CONSTANT block of Examples/Fraktal_Press_Demo/00_System/MAIN.TcPOU deliberately hold physical outputs off until the corresponding check is done. Until then the machine looks broken while the software is healthy:

  • CONTROL_CIRCUIT_MAPPING_CONFIRMED (default FALSE) — FB_PressIoDriver.M_WriteOutputs forces _000K951_A1 (SwitchControlOn) and _000K911_A1 (EnableControlOn) FALSE every cycle. Control On cannot energize, so the hardwired N54 D2 relay chain never closes and K985/K986 never enable the valves — nothing moves at all, even though the cylinder coils are written unconditionally. Set it only after verifying the K951/K911 electrical semantics on the cabinet. Per the N54 D2 signal table these are distinct signals (momentary button coil vs. bus/air-OK enable), yet both currently receive PowerHal.EnableRequestOut; confirm that is correct for your wiring before enabling.
  • USE_SIMULATION (default FALSE) — when TRUE, MAIN calls IoDriver.M_ClearOutputs() every cycle so no physical output is ever energized during virtual commissioning.

Demo-rig deviation: the E-stop mirror is NOT fail-safe

Section titled “Demo-rig deviation: the E-stop mirror is NOT fail-safe”

_000K910A (=000+S1-K910A:14, “Emergency Switch 1 Pressed”) is wired normally open on the demo rig — confirmed on hardware — so FB_PressIoDriver inverts it to produce the healthy mirror. A normally-open E-stop contact cannot distinguish “not pressed” from a broken wire, a pulled terminal or a dead input card: all read FALSE, and the mirror would report healthy. ISO 13850 / EN 60204-1 require a normally-closed contact so any break forces the stop.

This is tolerable only because the mirror is diagnostic and the hardwired N54 D2 relay chain remains the safety authority (Core §9). A production machine must rewire to NC and delete the inversion.

These are constants, so they cannot be written online. Changing one is a source edit in MAIN plus a download — deliberate and reviewable, rather than a live write from an HMI, XAE watch window or ADS client. The trade-off is intentional: switching to virtual commissioning now costs a download.

MAIN still publishes read-only mirrors (UseSimulation, ControlCircuitMappingConfirmed) so the gate state remains visible to diagnostics; they are reassigned from the constants every cycle and no logic reads them, so writing a mirror online changes nothing.

Read both off a running PLC before suspecting the control logic:

Terminal window
cd FraktalCore/HMI/gateway
dart run tool/probe_sim_flag.dart <amsNetId> [port]

If forcing the output in TwinCAT XAE works but the PLC never drives it, it is one of these gates — the terminal, wiring and process image are already proven good by that test.

Writing your first type (Quick-start, Core §1.1)

Section titled “Writing your first type (Quick-start, Core §1.1)”
  1. Copy scaffold/FB_TemplateCM/, rename Template → your type, reserve a reason band (Core §8.8) and record it in the registry.
  2. Declare your E_<Type>Command, ST_<Type>Hal, ST_<Type>ParCfg (keep SchemaVersion — §3.8).
  3. Write _M_Dispatch only (~15 lines): drive output → await sensor → _M_Complete() / _M_Fault(<band code>, …). Interlocks via FB_PermIntlk; the lifecycle is inherited.
  4. Turn the RED suite GREEN: fill the T2/T3/T5 expected values and run against the sim HAL (§2.6) — no rig. T1/T4 are already proven by FB_Base_Tests for every inheriting type.
  5. Wire once in the parent’s Setup (§3.11); the tile renders itself (§3.13).
Row Where proven
T1 handshake + Execute-drop reset FB_Base_Tests (once, for every inheriting type)
T2 first-out reason and SourcePath base mechanism in FB_Base_Tests; each type re-proves with its reasons (scaffold)
T3 interlock withholds output per type (scaffold, RED)
T4 abort, no self-resume FB_Base_Tests (once)
T5 recipe migrate-or-fault per type (scaffold, RED)
T6 rollup adopts child verbatim base mechanism in FB_Base_Tests (FB_ProbeEM); composites re-prove per Annex H §H.5
T7 link supervision FB_Connector_Tests (once, in the connector base)
T8/T9 tier rows per composite/Unit type (worked: FB_ClampEM_Tests rollup, FB_Unit_Tests)

Fraktal_Modules/ ships reusable module types (including Annex A/B’s FB_CylinderCM and FB_ClampEM) with their §8.8 band constants, simulation models, and configured device presets; their suites run in the same gate.


Built from FraktalCore/PLC/TwinCAT/README.md at revision a1163c7 of the Fraktal repository.