Annex K — Interoperability Mapping: Asset Administration Shell (AAS, IEC 63278 / IDTA Submodels)
Companion to Fraktal Core (Part I). Sibling of Annex J (MTP): MTP answers “how do I orchestrate this module”; AAS answers “what is this asset, across its whole lifecycle.” Core concepts projected: digital nameplate (§3.10.1), self-description (§3.10), model identity (§3.1b), alarms/history (§8.3), traceability (§8.11 / Annex E). Status: conceptual mapping + a shipped nameplate. §3.10.1’s field set is deliberately IDTA-02006-shaped so this projection is a serialization, not a redesign. Submodel element names below come from the published IDTA templates (admin-shell.io); verify against the exact template version chosen before export.
K.1 Why
Section titled “K.1 Why”The AAS (IEC 63278) is Industry 4.0’s standardized digital representation of an asset — identity, documentation, technical data, service history — packaged as submodels with dictionary-referenced semantics (ECLASS / IEC CDD) and exchanged as AASX packages. Fraktal’s runtime self-description (§3.10) covers behaviour; the AAS covers identity and lifecycle. §3.10.1 (the digital nameplate) is the bridge: it lives in the PLC, renders in the Fraktal HMI, and projects 1:1 onto the standard submodels.
K.2 Submodel map
Section titled “K.2 Submodel map”| Fraktal | AAS / IDTA submodel | Fit |
|---|---|---|
ST_Nameplate (§3.10.1): ProductUri, ManufacturerName, ProductDesignation, SerialNumber, YearOfConstruction, HW/FW/SW versions, OrderCode |
Digital Nameplate (IDTA 02006) — URIOfTheProduct (mandatory), ManufacturerName (multi-language property), ManufacturerProductDesignation, SerialNumber, YearOfConstruction, version fields |
Direct — by construction. The §3.10.1 field set was chosen to match. Note 02006 models ManufacturerName as multi-language; Fraktal’s single string exports as one language entry. |
DocumentationUrl (§3.10.1) |
Handover Documentation (IDTA 02004) | Partial-by-intent: Fraktal stores one link; 02004 models a classified document set (VDI 2770). The link points at the handover package rather than replicating its structure in the PLC. |
| Recipe/config schema (§3.8), timing parameters (§8.11) | Generic Technical Data (IDTA 02003) | Good. Exported as technical properties; live values stay on OPC UA (§3.10), not in the AAS. |
| Root model identity (§3.1b: ModelCode per root) | AAS asset kind/type vs instance distinction | Good. A Fraktal root Unit is an asset instance; its model is the type. |
| Module tree (§3.1 forest) | Hierarchical Structures / BOM (IDTA 02011) | Good. The same tree walk the HMI does emits the BOM hierarchy — a purchased CM (own nameplate, §3.10.1 cardinality rule) appears as a component asset. |
| Alarm/event history (§8.3), cycle stats (§8.11) | Time-series / service-record submodels | Deferred. These are operational data; exporting them into AAS is an historian concern (I_EventSink adapter), not a PLC one. |
K.3 Export path
Section titled “K.3 Export path”Like Annex J, an engineering-time projection of data the modules already publish:
- Walk a root Unit (same walk as the HMI): collect
Nameplateper module, the tree shape, and the config schema. - Emit an AASX package: one AAS for the root asset; Digital Nameplate submodel from
ST_Nameplate; BOM submodel from the tree (child modules with their own nameplates become component assets); Technical Data from §3.8/§8.11 parameters; the Handover Documentation submodel referencingDocumentationUrl. - Semantic IDs come from the IDTA templates (ECLASS IRDIs) — the exporter carries them; the PLC does not (the PLC stores values, the template supplies semantics).
Open-source tooling (AASX Package Explorer, aas-core SDKs, BaSyx) consumes the result; no Fraktal-aware client is needed on the receiving side.
K.4 Honest boundaries
Section titled “K.4 Honest boundaries”- The PLC ships the nameplate; the exporter is not implemented. What exists today:
ST_Nameplate+SetNameplatein the library, the §3.10.1 contract, sim data, and the HMI facet card. The AASX serializer is deployment work against the chosen IDTA template versions. - Single-language strings. IDTA multi-language properties export with one language entry; a multilingual deployment extends the exporter, not the DUT.
- Identity is not configuration. The nameplate is deliberately read-only from the HMI and outside §3.8/§7.7 — the AAS side agrees (nameplate data is manufacturer-authored, not operator-edited).
- AAS ≠ transport. The AASX is a package, not a live channel; live data remains OPC UA (§3.10). Where a live AAS server (e.g. BaSyx) is wanted, it is a client of the same OPC UA surface.
K.5 Checklist for an exporter
Section titled “K.5 Checklist for an exporter”- Root Unit exports as one AAS instance with a valid Digital Nameplate submodel (02006 mandatory fields present;
URIOfTheProductglobally unique). - Modules with non-empty nameplates appear in the BOM submodel (02011) as component assets with their own nameplates.
- Technical Data submodel values match the §3.8 config schema; no live process values leak into the AASX.
-
DocumentationUrlresolves and is referenced from the Handover Documentation submodel. - The AASX validates in AASX Package Explorer against the pinned template versions.
Built from Specification/Annexes/Annex_K_AAS_Mapping.md at revision a1163c7 of the Fraktal repository.