Fraktal OPC UA transport
This document defines the deployment boundary behind the generic HMI
PlcRepository. It does not change the module contract.
On a Windows/TwinCAT host the native default is now ADS, not direct OPC UA —
it is the faster native path and needs no TF6100 server. OPC UA remains a
first-class, selectable HMI transport for remote and non-Beckhoff PLCs. ADS is a
drop-in OpcUaSessionClient that emits the identical fraktal.opcua.snapshot.v1
document, so the mapper, config-manifest, and mailbox contracts apply unchanged
to both direct transports. Read-tier behavior is capability-negotiated: the
current direct ADS/OPC UA clients provide targeted/tiered reads, while the Web
gateway currently relays a complete server-side snapshot. The ADS
transport is specified in ADS_TRANSPORT_MIGRATION.md; the summary is below.
Platform routing
Section titled “Platform routing”| Flutter target | Transport | Implementation |
|---|---|---|
| Windows (TwinCAT) | direct ADS (native default) | fraktal_ads.dll (TcAdsDll) through dart:ffi in the fraktal-ads isolate |
| Windows (remote / non-Beckhoff) | direct OPC UA or the gateway | native ws/wss client; open62541 through dart:ffi |
| Linux / Android | Fraktal WebSocket gateway | native ws/wss client; direct C ABI remains source-compatible where packaged |
| Web | Fraktal WebSocket gateway | browser WebSocket client; the gateway owns the OPC UA session |
| Gateway → Siemens S7 (Fraktal/TIA) | S7 Web API (s7web://) |
WebApiSessionClient over one pinned HTTPS connection; licence-free (Part IV §11.1a) |
Browsers shall never attempt raw OPC UA TCP. Every transport delivers the same
flat fraktal.opcua.snapshot.v1 document to OpcUaSnapshotMapper, so discovery
and UI behavior cannot drift by platform or by transport.
ADS transport (native Windows/TwinCAT default)
Section titled “ADS transport (native Windows/TwinCAT default)”The native Windows client may connect over ADS with an ads://<AmsNetId>:<port>
endpoint (default ads://127.0.0.1.1.1:851, the local runtime; the wizard seeds
it and the operator confirms the machine’s AmsNetId). It is a dart:ffi client
in the dedicated fraktal-ads isolate over fraktal_ads.dll, which wraps
Beckhoff’s TcAdsDll using Beckhoff’s own headers so struct/datatype layout is
version-correct. The build self-skips when not on Windows or when TcAdsDll
is absent, so the HMI falls back to OPC UA and non-TwinCAT builds are unaffected.
- Discovery is a datatype-table walk:
SYM_UPLOADINFO2(0xF00F) sizes the symbol and datatype tables,SYM_DT_UPLOAD(0xF00E) uploads the datatype table (members reference their type by namespaced name, e.g.Fraktal_Core.ST_ModuleStatus, resolved recursively), andSYM_UPLOAD(0xF00B) lists top-level symbols; eachMAIN.*/ fieldbus symbol is expanded to leaves. The resulting flat path set feeds the unchanged mapper —MAIN.PneumaticPress.Status.StatebecomesPLC1/MAIN/PneumaticPress/Status/State(syntheticPLC1/prefix, dots→slashes), the same identity the OPC UA snapshot emits. - Reads use value handles (
SYM_HNDBYNAME0xF003→SYM_VALBYHND0xF005→SYM_RELEASEHND0xF006). The whole fast tier is read in one round trip by the ADS sum-commandSUMUP_READ(0xF080); a per-symbol path is kept as a fallback for runtimes that lack the sum service. Measured: steady-state snapshot ~15 ms (vs ~2.3 s reading 1.6k symbols individually). - Writes are typed handle writes; mode-change round-trips ~86 ms median
through the production repository path — the metric the OPC UA path only reached
after the read-tier work, and with none of the TF6100 licensing/TOFU/handle-pool
(
0x710) failure classes. - Read tiers map directly: the fast/slow tiers are read every snapshot (ADS
is fast enough that the slow-tier heartbeat is not required), and the
excluded set (config manifest + on-demand drill-down + fieldbus) is never
read cyclically — it is served by targeted
readValuescalls, identical to the OPC UA excluded tier.
ADS is Beckhoff-specific by design: it is the native fast path, while OPC UA stays
the portable multi-brand path — a PLC with a licensed OPC UA server integrates by
pointing the same HMI at opc.tcp://…. A Siemens CPU without that licence uses
the gateway’s s7web:// transport (below); Allen-Bradley uses its CIP gateway. Reconnect-on-router-loss and
first-snapshot handle batching are tracked as hardening in
ADS_TRANSPORT_MIGRATION.md §11.
Siemens S7 Web API transport (Fraktal/TIA)
Section titled “Siemens S7 Web API transport (Fraktal/TIA)”The gateway may connect to a Siemens S7-1500 / S7-1200 (≥ V4.5) CPU with an
s7web://<host>[:port] endpoint. WebApiSessionClient
(packages/fraktal_opcua_client) speaks the CPU’s own JSON-RPC 2.0 Web API over
HTTPS and emits the same fraktal.opcua.snapshot.v1 document, so the mapper,
manifest and mailbox contracts apply unchanged — no runtime licence is needed,
unlike the CPU’s OPC UA server. Measured on a CPU 1214C V4.7.3
(Siemens/Evidence/TIA_S1W_WEBAPI_2026-10-08.md):
- Trust is one pinned server certificate (
--plc-certificate, PEM or DER), checked on every new connection; system roots are never consulted. The CPU user (UMAC on S7-1200 V4.7) holds only read/write-process-data rights, and members without “Writable from HMI/OPC UA/Web API” refuse writes in the CPU (205), so the mailbox remains the single write surface even past the gateway. - Discovery browses every DB whose top level has a
Statusstructure, breadth-first in batched requests, and expands structures and arrays to scalar leaves (the Web API reads leaves only). Paths are spelled as on ADS:PLC1/<Root>/<Member>/Rows[3]/<Leaf>; Web API names quote every segment. - Cost is ≈ 57 ms per request + ≈ 15 ms per leaf; the CPU serves one request
at a time across sessions, so requests carry at most
--webapi-batchleaves (default 20). Slow and excluded tiers behave as on the native clients; a slow path is re-read every 10 s or onrefreshSlowPaths. - Connection. An S7-1200 TLS handshake costs ≈ 2.75 s, the CPU closes an idle
connection after 1–2 s, and
dart:ioHttpClientopened a new connection per request to it. The client therefore keeps ONE persistent TLS connection, serializes requests on it and sendsApi.Pingbefore the idle close. A request on a connection the CPU dropped is resent once on a new one — safe, because reads are idempotent and the PLC acts only on a changedSequence. - Session. One
Api.Login; an expired token (2, after 2.5 min idle) is renewed once and the call resent (a refused call applied nothing);Api.Loginis never sent with the old token (101). - Mailbox.
writeBatchwrites every argument in one request, then theSequencecommit alone — only if every argument was accepted. - Scalar encodings on the S7-1500 reference.
timebecomes Int32 milliseconds.ldtis a signed64-bit decimal string of Unix nanoseconds; the transport emits DateTime as an ISO UTC string with nine fractional digits, or zero for Core’s unset sentinel. Malformed or out-of-range LDT yields Bad status and no value. The generic HMI date parser retains microseconds.lint/ulintkeep exact decimal strings labelled Int64/UInt64; widewstringfields become String. These encodings passed the live client on simulated1516 V3.0/Advanced7; full Unit rendering and commands are separate gates (evidence).
Native ABI
Section titled “Native ABI”The native library exports create/connect/disconnect, snapshot, typed write and
error functions from native/opcua/fraktal_opcua_bridge.h. open62541 1.4.12 and
Mbed TLS 3.6.6 are pinned and vendored with their licenses. All native calls run
in the fraktal-opcua Dart isolate; the Flutter UI isolate never performs a
blocking browse/read/write.
The ABI exposes frk_opcua_connect_secure with an explicit profile, policy URI,
application URI, client certificate, private key, optional private-key
password, server/CA trust list, and optional revocation list. Secure profiles
force SignAndEncrypt; reconnect
reuses the same material and may not downgrade. Private-key bytes are cleared
after open62541/Mbed TLS configures the client. Credentials are process inputs,
not endpoint/query data or HMI settings JSON.
Four deployment profiles are defined:
| Profile | Channel / identity | Rule |
|---|---|---|
production |
trusted certificate + SignAndEncrypt + named TF6100 user |
Default; required for a network-connected production cell |
secure-anonymous |
trusted certificate + SignAndEncrypt + Anonymous token |
Transitional commissioning only; preserves channel and application authentication |
commissioning-anonymous |
None + Anonymous |
Troubleshooting/initial bring-up; gateway warns and auto-stops after a bounded TTL |
isolated-anonymous |
None + Anonymous |
Explicit exception for one physically isolated, unrouted PLC/HMI deployment |
Missing production material is a startup failure. A failed secure connection shall never retry with a weaker profile. Anonymous namespace/write rights shall be least-privilege. A network-connected production target shall disable the Anonymous/None exception after commissioning. A permanent isolated exception requires documented physical/network controls and ownership.
The direct Windows opc.tcp wizard path intentionally remains Anonymous/None
and logs a security warning; it is only for commissioning, troubleshooting, or
the isolated exception. The cross-platform production path is wss through the
gateway, so PLC credentials and OPC UA private keys remain under a dedicated
gateway service identity.
Online-change resilience
Section titled “Online-change resilience”A TwinCAT PLC online change reloads the TF6100 Data Access namespace and commonly tears the OPC UA session down. The native client is driven by explicit service calls (no open62541 event loop), so it recovers deliberately, not via auto-reconnect:
- Session loss — every snapshot checks the live channel/session/connect
status; if it degraded, the client reconnects with the cached endpoint and
clears the cached NodeId map, then re-browses. This is transparent: no command
is queued across the gap, and the HMI returns to
LIVEas soon as the session is back (aSTALE/DOWNblip only if the reconnect itself fails). - Structural change with a surviving session — reads against cached NodeIds
that no longer resolve (
BadNodeIdUnknown/BadNodeIdInvalid) are counted; a surge (≥20 % of cached variables gone) invalidates the discovery cache so the next snapshot re-browses the fresh tree (added/removed/renamed symbols). - Writes issued during the brief reconnect window are rejected, not queued
(§14); the operator re-issues once the HMI is
LIVEagain.
Reconnect attempts are naturally throttled by the connect timeout and the shared in-flight refresh, so a PLC that is genuinely down cannot starve the isolate.
Snapshot
Section titled “Snapshot”{ "protocol": "fraktal.opcua.snapshot.v1", "nodeCount": 123, "truncated": false, "namespaces": [ "http://opcfoundation.org/UA/", "urn:BeckhoffAutomation:Ua:PLC1" ], "values": { "PLC1/MAIN/PneumaticPress/Status/Name": "PneumaticPress", "PLC1/MAIN/PneumaticPress/Status/ModuleType": 1 }, "dataValues": { "PLC1/MAIN/PneumaticPress/OutImm/Pressure": { "status": 0, "type": "Double", "value": 4.2, "sourceTimestampUs": "1784613600123456", "serverTimestampUs": "1784613600124000" } }}dataValues is an additive v1 field carrying the OPC UA DataValue quality,
runtime scalar type, value when encodable, and optional timestamps. Timestamps
are Unix microseconds encoded as decimal strings so JavaScript cannot lose
64-bit precision. values remains the compatibility/discovery surface and
contains only Good-quality scalar values. A client may retain a Bad or Uncertain
tag from dataValues so an imported binding survives a transient fault, but it
shall render that tag unavailable and shall not chart or write from the stale
payload. Good status codes are classified by their OPC UA severity bits, not by
testing only for the literal zero status.
An adapter may add a deployment freshness envelope, version 1. Its optional
top-level freshnessBudget contains integer millisecond fields pollPeriodMs,
fastGoodMs, fastExpiryMs, slowPeriodMs, slowGoodMs, slowExpiryMs, and
schemaVersion: 1. Each period is positive and less than its Good limit, which
is less than its expiry limit. Values are bounded to 60,000 ms. These limits
belong to the measured deployment; they are not defaults for an entire binding.
With this envelope, sampleAgeMs is the monotonic age of the accepted complete
acquisition, measured conservatively from before I/O. Each DataValue also carries
its own ageMs and tier (fast or slow); an excluded native group uses the
slow limits when retained and refreshes only on targeted demand while excluded.
A visible table promoted to slow refreshes on the declared heartbeat. A native group
with any fast leaf remains fast after intersecting all viewers’ tier requests.
Cached replies advance ages without replacing acquisition timestamps. No
controller source UTC time is inferred from these ages.
At a Good limit a previously Good value becomes Uncertain (0x40000000, reason
read-late); at expiry it becomes Bad (0x80000000, read-expired). Existing
non-Good quality is never improved by aging. Invalid leaf metadata maps to Bad
(read-metadata-invalid). A present malformed/unknown budget, invalid complete
sample age, or disappearance of an established budget fails closed.
Budgeted complete polls renew on their declared start-to-start cadence with one acquisition in flight. When a read overruns its period, the next starts after completion instead of waiting for a later periodic-timer boundary; faster reads wait out the remaining period. Expiry still runs independently of pending work.
The repository uses a local monotonic clock and adds the snapshot RPC’s
elapsed time as a conservative transit allowance. A gateway may additionally
publish responseProcessingMs, bracketed from request handling to the exact
monotonic boundary at which source ages were calculated. The client subtracts
that server wait/read from the full RPC allowance and adds one millisecond for
clock resolution. Cached source ages/timestamps do not change; malformed,
nonfinite or negative brackets, or values larger than the RPC plus that
millisecond, fail closed. Missing brackets preserve the legacy full RPC
allowance. This avoids counting native acquisition twice without relaxing
Good/expiry limits. Its expiry timer runs independently of a pending RPC.
At the complete sample’s Good limit
it withdraws the interactive shell and cached Good data (STALE); at expiry it
reports DOWN. It also checks age synchronously before each write or queued
request. Only a fresh complete snapshot restores LIVE; partial mailbox/Ack
reads cannot renew it. Declared polling continues during initial manifest
hydration and long interactive operations once a valid tree exists. The delivery
timeout remains a separate limit. Older transports without this optional
envelope retain their existing polling policy and do not inherit its evidence.
The mapper recognizes a module only through Status : ST_ModuleStatus and
builds its HMI identity from published Status.Name values. Server-specific
prefixes such as PLC1/MAIN do not enter the Fraktal identity.
namespaces is diagnostic metadata read from the standard OPC UA
Server/NamespaceArray: if the PLC namespace is present while Objects exposes
only Server, the connected identity lacks browse rights; if it is absent, the
TF6100 Data Access NodeManager/TMC configuration was not loaded.
Native discovery is breadth-first and cached once per OPC UA session. Breadth
first ordering guarantees that shallow root contract/mailbox nodes are found
before implementation detail when a server publishes a large tree. Value nodes
are subsequently read in bounded service batches; the 500 ms repository refresh
does not recursively browse the namespace again. truncated=true means the
configured discovery cap was reached and is a commissioning defect: narrow the
published namespace or revise the contract-aware projection after measuring it,
instead of silently treating a partial tree as complete.
TF6100 may expose references held by recipe catalogs, I/O drivers, or control
coordinators as additional navigable paths to the same FB. The snapshot may
carry those values. Status.Name is a qualified dotted identity, so the mapper
accepts a candidate when its final browse-name segment equals the final segment
of Status.Name, deduplicates every module by the complete identity, and builds
parentage from the dotted identity prefix. Among multiple same-identity
candidates it selects the shallowest path; discarded aliases are logged as
opcua-aliases-discarded. This implements Part II §3.10’s rule that a
reference/owner alias is not another deployed module/root.
TF6100 commissioning access
Section titled “TF6100 commissioning access”The direct native HMI and the gateway’s commissioning-anonymous /
isolated-anonymous profiles use Anonymous with SecurityPolicy=None. The
following Anonymous setup applies only to those explicit exception profiles.
Production and secure-anonymous instead require a trusted client application
certificate and a matching SignAndEncrypt endpoint; production additionally
requires a named least-privilege TF6100 user.
TF6100 5.x (TwinCAT 4026) first requires a one-time Trust-On-First-Use
initialization before it publishes any Data Access namespace; until then an
Objects browse shows only Server and Initialization and the HMI reports
zero root Units. Initialize once from the OPC UA Configurator over a secured
endpoint (Basic256Sha256 / SignAndEncrypt) with a UserName admin identity —
a credential token cannot be sent over a None channel. Initialization then
disables the Anonymous token, so the anonymous commissioning access below must
be re-added afterward. On a usermode/standalone runtime the server lacks rights to
create its admin OS user during init; pre-create that account in Windows first.
Full procedure and the local-PC quick path are in
FIRST_PROJECT_AGENT_GUIDE.md §7.0 / §11.
In the OPC UA Configurator connected to the remote PLC, open Security and:
- Edit the existing Anonymous user and assign it to the built-in Users group. Configurator versions that offer only Guests, Users, and Administrator should use Users; do not create a second Anonymous user or grant Administrator for HMI data access.
- In the Users group’s namespace/default access, add
urn:BeckhoffAutomation:Ua:PLC1with Browse, ReadAttribute, and ReadValue. Namespace browse permission is required soPLC1andMAINare visible; granting access only at the root Unit cannot expose hidden ancestors. - If node permissions are used, add the deployed root Unit with depth
-1for inherited Browse/Read. Add Write only for itsHmiRequestsubtree. - Activate the changed server configuration and restart/reload TF6100 before retrying the HMI.
When the server trace accepts AnonymousIdentityToken, prints Roles assigned to session without any role entries, and returns only Server from an
Objects browse, these rights have not reached the active server configuration.
For TwinCAT TMC-Filtered publication, every deployed root Unit declaration is
explicitly marked with {attribute 'OPC.UA.DA' := '1'}. The marker is inherited
by the root’s children and makes the intended forest explicit. Fraktal does not
use TwinCAT’s definition-level enable marker because it also publishes
undeployed instances and reference aliases. A separately published GVL value
places the marker immediately before that variable, not before VAR_GLOBAL.
After activating a changed PLC project, restart/reload TF6100 so it imports the updated
Port_<ADS port>.tmc; an authorized identity browsing Objects shall then see
the configured Data Access device and a direct MAIN/<Root> path.
The inherited root marker must not publish implementation-only pointer,
interface-reference, or REFERENCE TO storage. Mark those fields with
{attribute 'OPC.UA.DA' := '0'} (or keep their owner outside the published
subtree). An Unsupported datatype ... UXINT importer entry means TF6100 skipped
such a pointer-like leaf. Fix an application-owned path and reload the TMC; the
Beckhoff system leaf TwinCAT_SystemInfoVarList._AppInfo.TComSrvPtr is outside
the Fraktal contract and can be ignored when the application namespace and roots
otherwise import correctly.
The native browser reads NodeCount and each active ChannelCount before it
enqueues the fixed topology arrays. Unused Nodes[] and Channels[] elements
therefore do not consume the browse/read budget. A snapshot carrying
truncated=true is rejected by both the gateway and HMI; gateway /readyz
remains degraded and no operator repository reaches LIVE. Raising the browse
cap is not an acceptance fix.
WebSocket gateway protocol
Section titled “WebSocket gateway protocol”The Web client sends:
{"protocol":"fraktal.opcua.gateway.v1","id":1,"method":"snapshot","params":{}}{"protocol":"fraktal.opcua.gateway.v1","id":2,"method":"write","params":{"path":"...","valueType":"boolean","value":true}}{"protocol":"fraktal.opcua.gateway.v1","id":3,"method":"writeBatch","params":{"writes":[{"path":".../HmiRequest/Kind","valueType":"int32","value":4},{"path":".../HmiRequest/Sequence","valueType":"uint32","value":19}]}}{"protocol":"fraktal.opcua.gateway.v1","id":4,"method":"discoverPaths","params":{}}{"protocol":"fraktal.opcua.gateway.v1","id":5,"method":"setReadTiers","params":{"revision":7,"slow":[41,42],"excluded":[90,91],"refreshSlow":false}}{"protocol":"fraktal.opcua.gateway.v1","id":6,"method":"readValues","params":{"revision":7,"indices":[90,91]}}The gateway replies:
{"id":1,"ok":true,"result":{"protocol":"fraktal.opcua.snapshot.v1","values":{},"dataValues":{}}}{"id":2,"ok":true,"result":true}{"id":4,"ok":true,"result":{"revision":7,"nodeCount":1234,"paths":["PLC1/MAIN/Unit/Status/State"]}}The gateway shall enforce origin/TLS/authentication policy, preserve browse paths and values exactly, serialize writes in request order, and never replay a write after reconnecting.
The gateway relays dataValues without normalizing status codes, types, or
timestamps. Native and Web HMIs therefore make the same quality decision from
the same server result.
discoverPaths returns the complete stable path vector plus a revision.
setReadTiers uses indices into that vector instead of repeating long browse
strings; stale revisions, duplicates, overlap, and out-of-range indices fail
closed. readValues accepts at most 512 unique indices per request. Clients
split larger logical reads into bounded calls and merge the results. A tier
profile accepts at most 20,000 indices and the whole request remains bounded to
256 KiB. The first snapshot on a connection includes the discovery vector;
after tier setup, cyclic snapshots carry an empty paths list so static browse
strings are not retransmitted. A rediscovery increments the revision and clears
every connection’s profile before new tiers can be installed.
One gateway owns one native PLC session, so connection-local tier mutations cannot be applied independently at that layer. The server therefore applies the intersection of every connected browser’s slow and excluded sets: a path is slowed or omitted only when all clients agree. A new or not-yet-configured browser temporarily requests the full live surface. This costs bandwidth during bootstrap but cannot make an existing operator view stale or incomplete.
The reference service is FraktalCore/HMI/gateway. It builds as a headless
Windows or Linux executable and shares the same native client package as the
Windows HMI. Its OPC UA profile is explicit and production is the default. The
process binds only to loopback. With --web-root, it also serves the matched
compiled Web HMI from the same listener. Release Web builds derive
ws:///wss://<page-origin>/fraktal, avoiding a second endpoint setting or a
separate static server. Browser and native Windows/Linux/Android clients use the
same protocol; the native client validates wss with the platform trust store
and may present a deployment-provisioned mTLS certificate/key or protected
bearer token. Such identity material is rejected for ws and is never stored in
the HMI connection-settings JSON. A remote client shall reach the service
through a same-host reverse proxy that terminates trusted TLS, authenticates
ordinary HMI access and the WebSocket upgrade, preserves Origin, and proxies
both HTTP and WebSocket traffic to loopback. The service checks exact configured
remote browser origins as a second boundary; origin checking is not
authentication. Installation and acceptance are specified in
WEB_HMI_GATEWAY_DEPLOYMENT.md.
Every gateway write is type-checked, globally serialized, attempted once, and
restricted to a published root HmiRequest subtree. Deployment may further
restrict reads/discovery with repeatable --read-root subtrees and eligible
Unit write roots with --write-root; the reference service is read-only until
at least one root is configured (an all-root commissioning override is
explicit). Invalid protocol versions, binary/oversize
requests, non-mailbox paths, and unapproved origins are rejected before OPC UA.
One HMI request uses writeBatch: all fields belong to one mailbox, paths are
unique, and Sequence : uint32 is the final write. The entire batch holds the
global write serializer, so another HMI cannot interleave fields. A standalone
Sequence write is rejected. The gateway remembers the last observed/committed
sequence per mailbox and rejects a duplicate or skipped commit, preventing two
HMI clients from consuming one another’s acknowledgement.
The gateway sends WebSocket Ping frames every 2 s. Native clients also enable a
2 s Ping/Pong watchdog; browser clients rely on the server heartbeat because
the browser WebSocket API does not expose control frames. A missing Pong closes
the socket. Snapshot transport failures reconnect with jittered exponential
backoff (250 ms to 5 s), but writes are never queued or replayed. The first
failed snapshot makes the HMI STALE and removes the operator shell; 5 s
without a good snapshot makes it DOWN. Cold-start connection failures retry
automatically (500 ms to 5 s) while the connection editor remains available
after the normal 30 s gate.
/livez reports process liveness. /readyz returns HTTP 200 only when the last
OPC UA operation succeeded and HTTP 503 after an observed OPC UA failure.
/healthz is the backward-compatible JSON summary. None returns PLC data.
All three replies include writeAccess: enabled reports whether the configured
gateway policy enables mutations, roots is the sorted list of configured write
roots, and allRootMailboxes reports an effective all-root scope. Explicit roots
take precedence over an all-root flag. Scope fields describe configuration even
when enabled is false. For the AB gateway, enabling mutations also requires a
configured bearer token and a wired mailbox writer; the reference Dart
gateway relies on the authenticated reverse proxy described above. These fields
contain no credentials and do not attest to proxy authentication, native write
permissions, PLC readiness, or a user’s PLC access level. plcReady and the PLC
command acknowledgement remain separate. An inert read-only QUERY_CONFIG
transaction does not make enabled true.
Config manifest — obscured static publication (Core §3.10.2)
Section titled “Config manifest — obscured static publication (Core §3.10.2)”Activation-static configuration is deliberately excluded from the cyclic
OPC UA tree with {attribute 'OPC.UA.DA' := '0'} and served on demand
through the request mailbox instead. This keeps the published address space
(and the server’s per-node ADS handle load) proportional to the live data:
| Obscured (manifest- or never-served) | Stays cyclically published |
|---|---|
Catalog/CatalogCount (manual commands) |
Status/* (discovery identity) |
AvailableModels/AvailableModelCount |
PLCopen outputs, counters, step, mode |
ModePolicy, StallTime |
SupportedModes/RunStylesPublished |
Nameplate, AlarmLog Meta/MetaCount |
ParCfg/StationCfg (editable fields) |
ST_BusNode identity (Name/TypeId/Address/ParentIdx/ChannelCount…) |
ST_BusNode.State, LinkOk |
ST_IoChannel identity/capability (Name/Address/Path/ModulePath/Dir/Kind/Unit/Forceable…) |
channel values/Forced/Quality/FaultActive/Diagnostic |
Protocol. The root Unit publishes ConfigRev : UDINT (seeded from boot
time, incremented on config writes, model changes, and re-activation) and
answers E_HmiRequestKind.QUERY_CONFIG (IntValue = page index) by filling
HmiResponse.ConfigPage — a bounded window whose read projection begins with
{Scope, Item, ValueText}. Scope is the dotted module identity ('#Fieldbus' for the bus
topology); Item reproduces the server’s array naming
(Catalog/Catalog[2]/Label, Nodes/Nodes[3]/Channels/Channels[5]/Name) so a
generic client rebuilds the exact browse path it would otherwise have read.
The enumeration is produced by a deterministic walk (I_ConfigSource. M_AppendConfig: base facets once in FB_ModuleBase, children recursed by the
composite base, Unit facets appended, projects may append — the press demo adds
its fieldbus topology via F_AppendTopologyConfig). FB_ConfigPager counts the
walk and stores only the requested window, so no full manifest buffer exists.
An entry is writable only when its append-only capability tail is complete:
WriteKey, non-zero WriteRevision, ConfigKind, ValueType, Writable,
RequiresReady, optional Minimum/Maximum, Unit, LabelKey, and optional
pipe-separated exact EnumDomain. Missing or conflicting metadata fails closed.
WRITE_CONFIG transports TargetPath=Scope, NameValue=WriteKey,
IntValue=WriteRevision, and TextValue=candidate; direct writes to Item are
not part of the contract. The PLC owning handler rechecks access, owner, revision,
type, domain/range, state, and transactional recipe invariants.
Parameter sets (Core ?3.8b). Append-only request kinds are SAVE_CONFIG_SET = 28,
LOAD_CONFIG_SET = 29, LIST_CONFIG_SETS = 30, EXPORT_CONFIG_SET = 32,
IMPORT_CONFIG_SET = 33, and DELETE_CONFIG_SET = 35; CAPTURE_CONFIG = 27
is the separate teach-capture request. Named operations use TextValue; Save
uses IntValue = ConfigKind. Each is CONFIG_SET gated. Loads are staged,
validate every record, and apply all or nothing. Model loads use the recipe
prepare/readiness/commit path; an adapter lacking that integration shall refuse.
List/export are reads and do not require READY. The persistence outcome remains
visible separately from the live configuration.
The client serializes a complete import/export, including every line and piece,
through the mailbox queue. Background config queries wait until that transfer
ends; a disconnected transfer is abandoned, never continued on a later link.
Core 0.22.0.0 adds two optional kinds. CREATE_MODEL = 37 uses NameValue
for the new code, IntValue for the source model index (0 running), or
BoolValue = TRUE and TextValue for a saved Model set. Positive ModelCapacity
is required before the HMI offers creation. Existing ordinals and active values
remain unchanged. EXPORT_CURRENT_CONFIG = 38, offered only with
Features/ExportCurrentConfig = TRUE, uses TextValue for an export name,
IntValue for ConfigKind, and DurationMs for the model index (0 running).
It returns the immutable document’s header as ConfigSetDocumentLine = 0;
EXPORT_CONFIG_SET continues lines 1..ConfigSetDocumentLines by that name on
the same connection. No saved-set slot is allocated. The PLC re-checks access
for every line. Older bindings expose no capability and refuse these requests.
HMI behavior. The repository fetches all pages when a forest is live and
the ConfigRev signature is new (startup, reconnect to a restarted PLC,
config write, changeover), synthesizes flat browse-path values from the
entries, and overlays them under the live snapshot before mapping. The
snapshot mapper receives typed configuration capabilities beside that read-value
overlay; facets and views remain transport-agnostic (the
mailbox works identically over the gateway). A server that publishes no
ConfigRev (older PLC library) is treated as fully published and never
queried. Absent manifest data degrades to empty facets, never an error.
Native read tiers (direct ADS / OPC UA)
Section titled “Native read tiers (direct ADS / OPC UA)”The direct native client reads the discovered contract at three rates, so the
2 Hz snapshot only pays for always-visible data. A single classifier
(opcua_field_tier.dart) is the source of truth; the bridge stays generic
(fast/slow read lists + an excluded set + targeted reads) and the mapper is
unchanged. The bridge emits the full discovered path list once per discovery so
the client can classify paths it never reads.
| Tier | Read rate | Data (examples) |
|---|---|---|
| fast | every snapshot (500 ms) | tiles, PLCopen state, counters, current step, active alarms (AlarmLog/Active — the global banner), OEE snapshot, live cycle profile, Unit SystemHealth/TimeQuality, and semantic SignalTower state |
| slow | once + ~2 s heartbeat | always-visible but slow-changing facets published redundantly on every module: Safety, ControlPower (read-only §9 status mirrors — display lag is bounded by the heartbeat; the PLC safety authority is unaffected) |
| on-demand | only while the owning view is visible | drill-down rings/trends excluded while closed; budgeted tiered clients promote visible tables to slow snapshots, otherwise use targeted batches: per module — AlarmLog/Ring, Profiler/History/StepStats, OeeTrend, Part/Result/Records, command Timing; and the fieldbus I/O tree (GVL_<Project>Fieldbus.Topology state/values) |
| config | manifest (above), never cyclic | activation-static identity (OPC.UA.DA := '0') — container-matched subtrees are excluded from the cyclic read; leaf-matched names stay cyclic (see below) |
Scoping the direct ADS read to the published contract
Section titled “Scoping the direct ADS read to the published contract”A transport shall not read outside the address space the contract publishes.
TF6100 enforces this for free: TMC-Filtered publication starts at the instances
marked {attribute 'OPC.UA.DA' := '1'} and their inherited children, so a
composition root’s private instances — part carrier, I/O driver, recipe
catalogue, config store, access provider, HAL structs, simulation controls —
are simply not there. ADS has no such filter: SYM_UPLOAD exposes the whole
program, so a direct client that scopes discovery by program prefix reads all of
it, at the cyclic rate, for data no view renders and no OPC UA client can see.
Two rules restore parity, both applied before tier classification:
- Outside the published roots. A path under a program container that owns a
discovered root Unit, but outside every such root, is off-contract: excluded
from the cyclic read and never given an activation scope. The containers are
derived from the discovered roots rather than matched against the name
MAIN, so this holds for any program name and for a peer forest (Core §3.1a). Before any root is discovered nothing is outside them — the first snapshot is how the roots become known. - Manifest-served containers. A subtree the PLC marks
OPC.UA.DA := '0'andM_AppendConfigre-serves under the same browse path is excluded from the cyclic read; the manifest overlay supplies it before the mapper runs. This is the container half of the config tier. The leaf half stays cyclic: leaf names such asNameandModuleTypealso occur on live structs, and a classifier cannot tell those apart from the path alone.
Discovery still enumerates excluded leaves, so they remain writable by path — which is what the §10.5.1 fieldbus demand gate needs. Over OPC UA and the gateway both rules are inert, because those paths are unpublished and never reach the classifier.
On-demand data is grouped by activation scope: a module’s drill-down data
scopes to its owning root Unit’s browse base; the fieldbus tree shares a reserved
scope. PlcRepository.setModuleDetailActive(rootPath, bool) and
setFieldbusViewActive(bool) gate them — AppState activates the selected
root’s scope while a module detail is shown, and the fieldbus page activates its
scope on mount/dispose. Sim treats both as no-ops; direct and gateway clients
apply the same classifier and view demand.
The optional containers set on setModuleDetailActive narrows the active
root to the selected tab’s visible, access-permitted cards. Null preserves the
whole scope for older callers; an empty set requests no detail. Sequence rows
belong to Sequence, event rings to Events/history, and cycle tables to cycle
analysis; parameter-set replies remain explicit post-request reads. Child
command timing belongs to the owning root’s scope. Authored controls derive
their demand from tag bindings, including visibility/rotation conditions.
Closing a view or changing its demand discards pending replies for that demand.
With a declared freshness envelope and a tiered client, demanded leaves move
from excluded to slow. Complete snapshots renew the consumed native records on
the declared heartbeat, avoiding repeated targeted leaf sweeps that can exceed
the Good window under concurrent load. Closing a view excludes its leaves again.
Tier updates are serialized with disjoint slow/excluded lists. Source ages and
quality remain authoritative; expired detail still becomes unavailable. A
non-tiered client keeps successful bounded detail sweeps on its own slow-period
cadence, without an extra complete-poll gap. Each batch retains its own read-start
age; no detail reply renews station health or another batch.
Targeted readValues requests may set includeDataValues: true. A supporting
gateway returns protocol: fraktal.opcua.read-values.v1, values, and
dataValues with each requested leaf’s original quality, timestamp and age.
The AB gateway can reuse a Good native record while its age is within the slow
period; otherwise it refreshes the requested group. Reuse changes no source
timestamp or complete-station health. Clients add local RPC/processing time to
the returned age. Scalar-only gateways retain their fresh targeted-read behavior
and remain compatible; unknown envelope versions are refused. Partial control
ACKs have their own acquisition quality/age and cannot renew station health.
Gateway parity status. The gateway preserves discovery, the config manifest,
mailbox ordering/acknowledgement, root scoping, PLC-side access checks, and the
same HMI-owned tier classifier as direct clients. Its bounded discoverPaths,
setReadTiers, and readValues operations make Web cyclic traffic proportional
to the consumed fast surface after the one-time bootstrap. Production acceptance
shall still measure a representative large forest through the packaged gateway;
source/protocol parity is not latency evidence for a particular IPC or TF6100
configuration.
Why this shape. The bounded history/trend arrays and the per-module
safety/power facets otherwise dominate the cyclic read (thousands of nodes) and
make TF6100 grow its ADS handle pool each poll (AdsIncreaseDynSymPool, a
0x00000710 handle burst), which stalls the single native worker isolate and
delays interactive commands — measured mode-change latency dropped from ~1.1 s
median to ~50 ms once the fast tier shrank from ~6.9k to ~2.7k nodes. Interactive
mailbox commands also mark the repository busy so the periodic refresh yields the
worker to the command’s small acknowledgement reads (Core §14). The manifest’s
fieldbus topology base is resolved from the discovered path set (its live members
are on-demand and absent from cyclic values).
OPC UA does not call IEC methods. Every root Unit publishes one
HmiRequest : ST_HmiRequest input and one HmiResponse : ST_HmiResponse
output. The client writes all request arguments first and writes Sequence
last. The Unit consumes each new sequence once, invokes the same gated methods
used by PLC callers, clears Secret, then publishes AckSequence last.
This commit marker prevents a scan from consuming a mixture of old and new arguments and gives native and gateway clients identical acknowledged writes. The HMI seeds its next sequence from the published request/ack values on every application start. It reserves the sequence before attempting the batch, so an ambiguous disconnect can never cause that command number to be reused.
E_HmiRequestKind is append-only across PLC and HMI. Core 0.3.0.0 appended
LAMP_TEST := 26; it carries no arbitrary output path or duration. The Unit base
rechecks MANUAL authorization and idle state, starts its configured bounded
semantic tower test, and acknowledges the exact sequence. A client never writes
individual lamp/horn members.
Core 0.4.0.0 also publishes each Unit’s HostEvents object as a bounded ring
(Ring, RingHead, Count, Capacity, Wrapped). It is read-only,
event-produced PLC data—not a command surface—and its ring belongs to the
on-demand tier. Clients derive traversal from the published Capacity, whose
current TC3 binding value is 32. E_HostEventKind is append-only and ordinal-identical in PLC and
HMI. A north-bound client uses Sequence for ordering and must retain
TimeSynchronized, Verdict, and ReasonCode rather than flattening quality or
result semantics.
Built from Specification/OPCUA_TRANSPORT.md at revision a1163c7 of the Fraktal repository.