Annex B — Worked Example: Clamp Equipment Module
Companion to Fraktal Core (Part I) exercised through the Fraktal/TC3 binding (Part II); slots under Core §12.
Core concepts demonstrated: EM orchestration through the handshake (§3.5/§6.3), parent-child rollup (§8.2), reusable sub-trees via Setup (§3.11). / TC3 mechanics used: OPC.UA.DA pragmas (TC3 §3.10), member FB_init ordering that motivates Setup (TC3 §3.11).
Reference implementation — illustrative, not compile-tested; validate against the pinned TwinCAT version and your HAL.
This annex builds the Equipment Module tier (§3.5, §6.3) and shows the three things a CM example can’t: an EM orchestrating child Control Modules through the handshake, a short non-looping step chain, and the parent-child diagnostic rollup (§8.2) that carries a child’s first-out reason up to the operator.
The example is a synchronized dual clamp: a FB_ClampEM holding two clamp cylinders. Each cylinder is itself a Control Module — a cylinder plus its two position sensors (extended/retracted), the “clamp = cylinder + 2 sensors” leaf — built on the Annex A pattern. The EM exposes two commands, CLAMP and UNCLAMP, that string the cylinder commands together and add no device logic of their own (§3.5).
ClampStation (FB_ClampEM, Equipment Module) ├─ CylA (FB_CylinderCM, Control Module) ── HAL: ExtendOut/RetractOut, ExtendedFb/RetractedFb └─ CylB (FB_CylinderCM, Control Module) ── HAL: …B.1 The cylinder Control Module (surface)
Section titled “B.1 The cylinder Control Module (surface)”The cylinder CM follows Annex A exactly (PLCopen handshake, four-structure contract, first-out diagnostic, interlocks in Ladder), so only its surface and reasons are shown here. Note it provides Setup(...) for nested use (§3.11).
{attribute 'qualified_only'}TYPE E_CylinderCommand : (NONE := 0, EXTEND := 1, RETRACT := 2) DINT;END_TYPE
// E_Reason additions — cylinder CM band 10100–10199// CYL_NOT_EXTENDED := 10101 // ExtendedFb not made within MoveTimeout// CYL_NOT_RETRACTED := 10102 // RetractedFb not made within MoveTimeout// CYL_BOTH_SENSORS := 10103 // both feedbacks active → wiring/jam fault
TYPE ST_CylinderHal : STRUCT ExtendOut, RetractOut : BOOL; // outputs ExtendedFb, RetractedFb : BOOL; // the two position sensorsEND_STRUCT END_TYPE
// Annex A/B pattern on the base class: the type is ONLY its device logic.// Execute/Abort arrive through ExecuteCommand/AbortCommand, and Busy/Done/Error/// Aborted/ErrorID, first-out stamping, rollup and publication are base-owned (§2.2).FUNCTION_BLOCK FB_CylinderCM EXTENDS FB_ControlModuleBaseVAR_INPUT Command : E_CylinderCommand; ParCfg : ST_CylinderParCfg; // SchemaVersion, MoveTimeout … ParCmd : ST_CylinderParCmd; // latched by the base on the Execute rising edgeEND_VARVAR_OUTPUT OutCmd : ST_CylinderOutCmd; // valid on Done OutImm : ST_CylinderOutImm; // Extended, Retracted, Diagnostic (ST_Diagnostic) Intlk : FB_PermIntlk; // conditions are DECLARED BY THE APPLICATION, not by this typeEND_VARVAR {attribute 'OPC.UA.DA' := '0'} _hal : REFERENCE TO ST_CylinderHal; _tMove : TON;END_VAR
METHOD Setup : BOOL // late binding for nested use (§3.11)VAR_INPUT Name : STRING(80); HalRef : REFERENCE TO ST_CylinderHal; Recipe : I_RecipeProvider; END_VAR THIS^._hal REF= HalRef; // No interlock is named here. "Area safe" / "Air pressure OK" are station facts, and a // reusable library cannot name them for a station it has never seen: the application // supplies them through DeclareCondition/SetCondition and the type only reads Intlk.AllOk (§7.2, §9.2). // recipe wiring as Annex A …Behaviour (body as Annex A): EXTEND drives ExtendOut, waits ExtendedFb within ParCfg.MoveTimeout → _M_Complete(), else _M_FaultStopped(Code := PL_ModuleReasons.CYL_NOT_EXTENDED, Text := 'std.error.cylinderNotExtended'); RETRACT is the mirror. Status.Diagnostic.SourcePath is the cylinder’s own browse path (e.g. ClampStation.CylA).
B.2 Clamp EM types
Section titled “B.2 Clamp EM types”{attribute 'qualified_only'}TYPE E_ClampCommand : (NONE := 0, CLAMP := 1, UNCLAMP := 2) DINT;END_TYPE
// E_Reason additions — clamp EM band 11000–11999// CLAMP_NOT_CONFIRMED := 11001 // both cylinders Done but a clamped sensor not held after settle
TYPE ClampParCfg : STRUCT SettleTime : TIME := T#150MS; // dwell before confirming ConfirmTimeout : TIME := T#1S;END_STRUCT END_TYPE
TYPE ClampOutCmd : STRUCT Clamped, Unclamped : BOOL; END_STRUCT END_TYPE
TYPE ClampOutImm : STRUCT Clamped, Unclamped : BOOL; Diagnostic : ST_Diagnostic; // own stall reason, or a rolled-up child reason (B.4)END_STRUCT END_TYPEB.3 The Equipment Module (ST step chain)
Section titled “B.3 The Equipment Module (ST step chain)”The EM holds its children as outputs, so they publish on the module tree and the generic rollup
walk (§3.2) reaches them without a parallel I_ControlModule array. Its command is a short step
chain that completes — it does not loop (§6.3).
// Annex B on the EM base: orchestration only, no device logic (§3.5); rollup §8.2.// Publication is inherited from the explicitly marked deployed root instance.FUNCTION_BLOCK FB_ClampEM EXTENDS FB_EquipmentModuleBaseVAR_INPUT Command : E_ClampCommand; ParCfg : ST_ClampParCfg; ParCmd : ST_ClampParCmd;END_VARVAR_OUTPUT CylA, CylB : FB_CylinderCM; // children are outputs: published, and reached by the rollup walk OutCmd : ST_ClampOutCmd; OutImm : ST_ClampOutImm;END_VARVAR {attribute 'OPC.UA.DA' := '0'} _recipe : I_RecipeProvider; _step : INT; _tSettle : TON;END_VAR
// ---- one-shot wiring (called from the Unit's init, §3.11) ----METHOD Setup : BOOLVAR_INPUT Name : STRING(80); HalA, HalB : REFERENCE TO ST_CylinderHal; Recipe : I_RecipeProvider; END_VAR CylA.Setup(Name := CONCAT(Name, '.CylA'), HalRef := HalA, Recipe := Recipe); CylB.Setup(Name := CONCAT(Name, '.CylB'), HalRef := HalB, Recipe := Recipe);
// ---- cyclic body: orchestration only; the base owns the handshake ----METHOD PROTECTED OnCyclicOnCyclic := SUPER^.OnCyclic();_M_TickChildren(); // children stay live, so their status is always currentThe command body (one method serves both directions; confirmExtended decides which feedback to verify):
METHOD PROTECTED _M_DispatchVAR_INPUT Dir : E_CylinderCommand; END_VARVAR extend : BOOL; END_VAR extend := (Dir = E_CylinderCommand.EXTEND);CASE _step OF 10: // command both cylinders together (parallel) CylA.Command := Dir; CylA.ExecuteCommand(Dir); CylB.Command := Dir; CylB.ExecuteCommand(Dir); _M_Wait('Clamping'); // pending reason while children run _step := 20;
20: // wait both Done — or roll up the first child Error (B.4) IF CylA.Error OR CylB.Error THEN _M_RollupFault(); ELSIF CylA.Done AND CylB.Done THEN _tSettle(IN := TRUE, PT := ParCfg.SettleTime); _step := 30; END_IF
30: // settle, then confirm both feedbacks held IF _tSettle.Q THEN _tSettle(IN := FALSE); IF (extend AND CylA.OutImm.Extended AND CylB.OutImm.Extended) OR (NOT extend AND CylA.OutImm.Retracted AND CylB.OutImm.Retracted) THEN OutCmd.Clamped := extend; OutCmd.Unclamped := NOT extend; _M_Complete(); ELSE _M_FaultN(Code := PL_ModuleReasons.CLAMP_NOT_CONFIRMED, Text := 'std.error.clampNotConfirmed'); END_IF END_IFEND_CASEThe EM adds no device logic — it only sequences the cylinder CMs’ existing EXTEND/RETRACT commands through the handshake (§3.5), plus an EM-level settle/confirm.
B.4 Parent-child diagnostic rollup (the point of this annex)
Section titled “B.4 Parent-child diagnostic rollup (the point of this annex)”When a child cylinder can’t finish, the EM does not invent a reason — it adopts the child’s first-out diagnostic (§8.2), so the message names the exact device and cause:
METHOD PRIVATE _M_RollupFault : BOOL // Adopt the first faulted child's diagnostic VERBATIM — reason, SourcePath and Since (§8.2). // No parallel I_ControlModule array is kept: the children are published members, and the // base's rollup walk already reaches them. IF CylA.FaultActive THEN _M_AdoptFault(CylA.GetFaultSummary()); ELSIF CylB.FaultActive THEN _M_AdoptFault(CylB.GetFaultSummary()); END_IF CylA.AbortCommand(); CylB.AbortCommand(); // stop the partner safelySo if CylB’s cylinder never reaches its extended sensor, the chain is:
Unit step "Clamp" ──awaits──▶ ClampStation.CLAMP (EM, Busy on step 20)ClampStation step 20 ──awaits──▶ CylB.DoneCylB ──Error──▶ ReasonCode = CYL_NOT_EXTENDED, SourcePath = "ClampStation.CylB"The EM’s Status.Diagnostic becomes exactly { CYL_NOT_EXTENDED, "ClampStation.CylB", "Cylinder did not reach extended" }, the Unit’s stall walk (§6.9) reads it through the EM’s GetFaultSummary, and the operator sees “ClampStation.CylB: cylinder did not reach extended” — a precise, device-naming root cause produced with no hand-coded conditions at the EM or Unit level, just the standard rollup.
B.5 Instantiation & the Unit step that commands it
Section titled “B.5 Instantiation & the Unit step that commands it”ClampStation is wired once via Setup (§3.11), injecting its name and the two cylinder HAL maps:
VAR ClampStation : FB_ClampEM; END_VAR
// in the Unit's init (one shot):ClampStation.Setup(Name := 'ClampStation', HalA := Hal.CylA, HalB := Hal.CylB, Recipe := LineRecipe);A step in the Unit’s AUTO mode chain (§6.2) commands the whole EM through the same PLCopen handshake it would use for any module — the Unit neither knows nor cares that two cylinders are involved:
// Unit AUTO chain, step N200 "Clamp part"IF NOT ClampStation.Busy AND NOT ClampStation.Done THEN ClampStation.Command := E_ClampCommand.CLAMP; ClampStation.Execute := TRUE;END_IFIF ClampStation.Done THEN ClampStation.Execute := FALSE; // Done advances the chain (§6.5)END_IFIF ClampStation.Error THEN // divert; reason already rolled up in ClampStation.ErrorID / .Status.DiagnosticEND_IFClampStation.Cyclic (its body above) drives CylA/CylB every scan, so the children stay live whether or not a command is running.
B.6 HMI (§3.13)
Section titled “B.6 HMI (§3.13)”The EM is rendered by laying out its children’s tiles — the automatic child view of §3.13:
Station ▸ ClampStation (EM tile: name, state LED ← ExecState) ├─ CylA (child tile: Extended/Retracted LEDs, manual EXTEND/RETRACT) └─ CylB (child tile: …)| View | Binding |
|---|---|
| Tile | name; state LED ← ExecState; Clamped/Unclamped LEDs ← OutCmd; quick Clamp / Unclamp buttons; the two cylinder tiles beneath it. |
| Detail | manual Clamp / Unclamp (release-gated, §7.6); the live Diagnostic.Description line — which, on a child fault, already reads “ClampStation.CylB: cylinder did not reach extended” via the rollup; tap-through to each cylinder’s own detail view. |
The operator can therefore diagnose from the EM screen and drill straight to the offending cylinder — the same parent→child path the PLC tree and the OPC UA model already define, with no station-specific screen building.
B.7 What this annex demonstrated
Section titled “B.7 What this annex demonstrated”- An Equipment Module orchestrating Control Modules purely through the PLCopen handshake, adding no device logic (§3.5).
- A short, completing step chain for an EM command, vs. the Unit’s looping mode chain (§6.2 vs §6.3).
- Parent-child rollup: the EM and Unit report a child’s exact first-out reason and source path with zero per-level diagnostic code (§8.2, §6.9).
- A reusable sub-tree wired by
Setup(...)because memberFB_initruns before the parent’s (§3.11). - Generic HMI: the EM renders its child tiles and surfaces the rolled-up reason, drill-through following the same tree (§3.13).
End of Annex B (draft).
Built from Specification/Annexes/Annex_B_Clamp_EquipmentModule.md at revision a1163c7 of the Fraktal repository.