Annex E — Worked Example: Traceability & MES Integration

Companion to Fraktal Core (Part I) exercised through the Fraktal/TC3 binding (Part II); slots under Core §12. Core concepts demonstrated: traceability & part context (§3.16), ISA-95 host-event mapping (§11.6), shared reason vocabulary (§8.8). / TC3 mechanics used: SysTime timestamps (Core §2.7 / TC3 §2.7). Reference implementation — illustrative, not compile-tested; validate against the pinned TwinCAT version and your carrier/host transport.

This annex builds the traceability contract (§3.16) and its MES/ISA-95 mapping (§11.6), showing what the recipe-only annexes (A–C) don’t: part identity and results moving up. It reuses the Annex A–C station, adds a carrier reader at infeed, and shows the four part-lifecycle events carrying a NOK whose cause is the same first-out reason that would have stopped the machine — written back to the carrier and emitted to MES as an ISA-95 transaction, with no separate reject-code scheme.

InfeedUnit (FB_InfeedUnit : FB_Unit) ← Annex C
├─ Carrier (I_PartCarrier, injected — RFID reader) ← here
├─ Separator1 / ClampStation / FixtureUnit ← Annexes A–C
└─ HostEvents (FB_HostEventPublisher; optional sink) ← here (§11.6)

E.1 Part context & the source-agnostic carrier (§3.16)

Section titled “E.1 Part context & the source-agnostic carrier (§3.16)”
TYPE ST_PartContext : STRUCT
Uid : STRING(64); Present : BOOL; CarrierKind : E_CarrierKind;
Result : ST_PartResult; Parents : ARRAY[1..MAX_GENEALOGY] OF STRING(64);
END_STRUCT END_TYPE
TYPE ST_PartResult : STRUCT
Verdict : E_Verdict; // NONE | OK | NOK | REWORK
ReasonCode : E_Reason; // first NOK reason — same vocabulary as a fault (§8.8)
Records : ARRAY[1..MAX_RESULTS] OF ST_MeasRecord;
StationPath : STRING(255); Stamp : DT; // synchronized clock (§2.7)
END_STRUCT END_TYPE
INTERFACE I_PartCarrier
METHOD ReadContext : BOOL (VAR_IN_OUT Ctx : ST_PartContext); // FALSE → CARRIER_READ_FAILED
METHOD WriteResult : BOOL (Ctx : ST_PartContext); // FALSE → CARRIER_WRITE_FAILED
END_INTERFACE

The carrier is injected exactly like I_RecipeProvider (§3.8), so RFID, Data Matrix, or a host-by-position lookup is configuration, not code.


E.2 The Unit reads, accumulates, writes, and emits

Section titled “E.2 The Unit reads, accumulates, writes, and emits”

Capture hangs off the existing AUTO mode chain (§6.2) at defined points — no new sequencing:

METHOD PRIVATE _M_AutoChain
CASE _step OF
5: // ── station entry: confirm identity ──────────────────────────────
IF NOT _M_PartReceived() THEN RETURN; END_IF // reads + emits once
IF Part.Uid <> _expectedUid AND _expectedUid <> '' THEN
_M_Fault(E_Reason.PART_ID_MISMATCH, 'Part id mismatch'); RETURN;
END_IF
_step := 10;
10: _M_PartStarted(); // alarm log + host projection
_step := 20;
// … steps 20–40: Separate / Clamp / Process / Unclamp as Annex C …
// each step that detects a child Error records it into the result:
// IF ClampStation.Error THEN
// _part.Result.Verdict := E_Verdict.NOK;
// _part.Result.ReasonCode := ClampStation.GetFaultSummary().ReasonCode; // CYL_NOT_EXTENDED
// _M_FinishPart(); RETURN;
// END_IF
50: // ── good completion ──
_part.Result.Verdict := E_Verdict.OK;
_M_FinishPart();
IF NOT _stopReq THEN _step := 5; ELSE _exec := E_ExecState.READY; _step := 0; END_IF
END_CASE

_M_FinishPart stamps, writes back before announcing processed, then emits — OK or NOK by the same path:

METHOD PRIVATE _M_FinishPart
_M_PartProcessed(Verdict := _part.Result.Verdict,
Reason := _part.Result.ReasonCode); // write-before-event, host + NOK projection

The inherited helpers own both the §8.3 lifecycle entry and its §11.6 host projection; application chains do not call a host transport directly. On Unit ERROR entry the base emits EVENT_PART_PROCESSING_ABORTED and PROCESSING_ABORTED, adopting the first-out reason when needed — the part leaves known-incomplete, never silently.


E.3 NOK carries the machine’s own first-out reason

Section titled “E.3 NOK carries the machine’s own first-out reason”

When CylB never reaches its sensor (the Annex B trace), the clamp EM rolls up CYL_NOT_EXTENDED @ "InfeedUnit.ClampStation.CylB". Traceability adopts that same reason as the part verdict — no parallel reject taxonomy:

ClampStation ──Error──▶ CYL_NOT_EXTENDED @ InfeedUnit.ClampStation.CylB
↓ (recorded into _part.Result)
ST_PartResult = { NOK, CYL_NOT_EXTENDED, StationPath="InfeedUnit", Stamp=… }
↓ WriteResult → carrier ; Emit(EVENT_PART_PROCESSED) → host

So the reject analysis on the MES reads “NOK — cylinder did not reach extended @ ClampStation.CylB” — the operator’s HMI message and the quality record are the same sentence, generated once.


Every Unit publishes the bounded HostEvents : FB_HostEventPublisher ring. A deployment that also needs push delivery injects I_HostEventSink, mapping the same fixed records to ISA-95 (IEC 62264) transactions; OPC UA A&C, socket/REST, or MQTT delivery is composition, not application sequence code:

In-PLC event (§3.16) Host / ISA-95 transaction
EVENT_PART_RECEIVED material/product tracking — arrival at resource (StationPath)
EVENT_PART_PROCESSING_STARTED production-response start
EVENT_PART_PROCESSED production response + quality (Verdict, ReasonCode, genealogy)
EVENT_PART_PROCESSING_ABORTED production response — aborted, with reason

Each payload carries StationPath (§4.8), Uid, the synchronized Stamp (§2.7), Verdict, and ReasonCode (§8.8) — a self-describing, reason-coded record an ISA-95/B2MML MES consumes without a bespoke driver. Commands into the cell (work order, expected Uid) arrive through the recipe/type path (§3.8) and are treated as untrusted input (§14).


A consumed component (e.g. a sub-assembly scanned at a feeder) is appended to Parents before EVENT_PART_PROCESSED, so the production response carries the as-built genealogy:

_part.Parents[1] := _componentScan.Uid; // built-into-this part

InfeedUnit mode: AUTO ▾ State ● BUSY
part: VIN-…7F3 ● NOK · "ClampStation.CylB: cylinder did not reach extended"
View Binding
Tile live part Uid; Present; verdict LED ← Result.Verdict.
Detail result record (Records), genealogy (Parents), and the ReasonCode line — the same sentence the diagnostic walk shows; drill-through to the offending child (ClampStation.CylB).

  • A source-agnostic part carrier (I_PartCarrier) mirroring the recipe provider — RFID/Data-Matrix/host as configuration (§3.16).
  • The four canonical lifecycle events raised at fixed mode-chain points, with carrier write-back before “processed” (§3.16).
  • NOK reuses the machine’s first-out reason — one vocabulary for faults and rejects, one sentence on HMI and MES (§8.8, §6.9).
  • A fixed host-event set mapped to ISA-95 transactions, self-describing and reason-coded, consumable by a B2MML MES (§11.6), with host commands treated as untrusted input (§14).

End of Annex E (draft).


Built from Specification/Annexes/Annex_E_Traceability_MES.md at revision a1163c7 of the Fraktal repository.