Annex F — Worked Example: PackML / OPC UA Line-Coordination Profile
Companion to Fraktal Core (Part I) exercised through the Fraktal/TC3 binding (Part II); slots under Core §12.
Core concepts demonstrated: PackML projection of the native state/mode model (§11.7, §6.6, §3.4), Admin group from §8/§8.11 contracts. / TC3 mechanics used: OPC UA server exposure of the PackMLObjects folder (TC3 §11.1).
Reference implementation — illustrative, not compile-tested; validate against the pinned TwinCAT version and the OPC 30050 companion model.
This annex projects the Annex C InfeedUnit onto the PackML profile (§11.7) — the OMAC state machine and PackTags exposed over OPC UA (OPC 30050) — so a line controller coordinates the cell with no bespoke driver, while the native ExecState/mode model (§6.1, §3.4) stays the internal source of truth. The point: PackML here is a projection of contracts the standard already has (state, modes, alarms, counters), not new logic.
Line controller ──OPC UA (PackTags)──▶ InfeedUnit/PackMLObjects │ Command / Status / Administration ▼ FB_PackMLAdapter ──reads/calls──▶ FB_InfeedUnit (Annex C)F.1 State-machine mapping (§11.7.1)
Section titled “F.1 State-machine mapping (§11.7.1)”The adapter derives the PackML state every scan from the Unit’s native execution state and its Stop/Hold/Abort/suspend conditions:
METHOD PRIVATE _M_MapState : E_PackMLState IF _unit.FaultActive THEN _M_MapState := SEL(_clearing, E_PackMLState.Aborting, E_PackMLState.Clearing); // → Aborted between ELSIF _unit.Blocked OR _unit.Starved THEN // §8.11 _M_MapState := E_PackMLState.Suspended; ELSE CASE _unit.State OF // E_ExecState (§6.1) E_ExecState.READY: _M_MapState := E_PackMLState.Idle; E_ExecState.BUSY: _M_MapState := SEL(_starting, E_PackMLState.Execute, E_PackMLState.Starting); E_ExecState.DONE: _M_MapState := E_PackMLState.Complete; // via Completing E_ExecState.ERROR: _M_MapState := E_PackMLState.Aborted; E_ExecState.ABORTED:_M_MapState := E_PackMLState.Stopped; // via Stopping END_CASE END_IF| Native (§6.1/§8.2/§8.11) | PackML state |
|---|---|
| READY/idle → Start | Idle → Starting → Execute |
| BUSY cycling | Execute |
Stop-after-cycle (OnModeExit, §3.14) |
Completing → Complete / Stopping → Stopped |
| Hold (§6) | Holding → Held → Unholding |
| Blocked/Starved (§8.11) | Suspending → Suspended |
| Fault hold (§8.2) | Aborting → Aborted → Clearing |
F.2 Unit-mode mapping & methods (§11.7.2)
Section titled “F.2 Unit-mode mapping & methods (§11.7.2)”SetUnitMode / SetMachSpeed map onto the native SetMode (§3.3) and recipe speed; an unsupported mode reuses the graceful rejection of §3.7:
METHOD SetUnitMode : BOOLVAR_INPUT UnitMode : E_PackMLMode; END_VAR SetUnitMode := _unit.SetMode(_M_ToNativeMode(UnitMode)); // FALSE if _M_Supports() = FALSE (§3.7)
// E_Mode → PackML Unit Mode: AUTO→Producing · MANUAL→Manual · CHANGEOVER/CALIBRATION/HOME→MaintenanceF.3 PackTags — projection, not new logic (§11.7.3)
Section titled “F.3 PackTags — projection, not new logic (§11.7.3)”The three groups are read straight from existing contracts:
// ── Command (consumed from the line) ───────────────────────────────Cmd.UnitMode → SetUnitMode(...) // §3.4Cmd.CntrlCmd → Start / Stop / Hold / Reset / Abort (§3.3 lifecycle)Cmd.MachSpeed → _unit.SetSpeed(...) // recipe speed (§3.8)
// ── Status (published to the line) ─────────────────────────────────Sts.StateCurrent := _M_MapState(); // F.1Sts.UnitModeCurrent := _M_FromNativeMode(_unit.ModeActive);Sts.MachSpeedActual := _unit.SpeedActual;
// ── Administration (consumed by higher-level systems) ──────────────Adm.Alarms[i] := { _alarm.ReasonCode, _alarm.Description, _alarm.Severity }; // §8, §8.8Adm.StopReason := _unit.GetFaultSummary().Description; // first-out (§6.9)Adm.ProdProcessedCount := _stationMon.GoodCount + _stationMon.NokCount; // §8.11Adm.ProdDefectiveCount := _stationMon.NokCount; // §8.11Adm.AccTimeSinceReset := _stationMon.AccTime;The Admin group is precisely where the §8 alarms, the §6.9 first-out stop reason, and the §8.11 counters surface to OEE/line systems — no values are invented for PackML.
F.4 Coexistence & exposure (§11.7.4)
Section titled “F.4 Coexistence & exposure (§11.7.4)”The adapter is exposed in a PackMLObjects folder on the cell’s OPC UA server (§11.1); the native interface and the ISA-95 host events (§11.6, Annex E) are unaffected and run alongside. A line controller issuing CntrlCmd := Start with UnitMode := Producing drives the cell through SetUnitMode→SetMode(AUTO) and Start→native Start (§3.3) — the AUTO chain of Annex C runs unchanged, and the line reads Execute, then live counters, then on a clamp fault sees Aborted with StopReason = "ClampStation.CylB: cylinder did not reach extended".
F.5 What this annex demonstrated
Section titled “F.5 What this annex demonstrated”- The native model projected onto the full PackML state machine and PackTag groups (Command/Status/Admin) — a conformance option (§11.7), not a rewrite.
SetUnitMode/SetMachSpeedmapped ontoSetMode/recipe, reusing graceful mode rejection (§3.7).- The Admin group sourced from existing contracts — §8 alarms, §6.9 first-out reason, §8.11 counters — so PackML adds an interface, not logic.
- Coexistence: PackML, ISA-95 host events (Annex E), and the native control interface on one server, over the same browse paths (§4.8).
End of Annex F (draft).
Built from Specification/Annexes/Annex_F_PackML_OPCUA_Profile.md at revision a1163c7 of the Fraktal repository.