Finishing the PLC CI gate — runbook
Companion to TWINCAT_XAE_WORKFLOW.md. That guide records what the gates do and
what was measured; this one is the ordered set of actions that takes the PLC
half of CI from where it stands to the §5.7 bar.
Where it stands (2026-08-16). PLC object check ran green on commit
0e16d51 — five steps, all five solutions, 2 m 44 s, from a clean clone. That is
the first licensed PLC compilation this repository has had in a hosted gate.
PLC TcUnit is skipped by design. The runner then de-registered itself.
Read §A and §B before doing anything: §B contains two decisions that change what §C and §D are worth doing.
Decisions taken (2026-08-16)
Section titled “Decisions taken (2026-08-16)”Recorded here because §C and §D branch on them, and because a decision that only lives in a conversation gets re-litigated.
| Decision | Consequence | |
|---|---|---|
| Autostart rule | §5.7 stands unchanged. Not narrowed | C-1 is not implemented |
| Runtime gate | Stays manual, by the §6.2 operator procedure | §C and §D are out of scope; §E item 2 is not pursued |
| Licensing | Stay on trial; may change if the project warrants it | Checks run advisory, never required; §E item 4 out of scope |
| Isolated runtime | Hold. Not standing up the isolated VM yet | Evidence stays qualified as development-runtime |
| Runner | On-demand, never left listening | Registration persists; run.cmd started deliberately, see §A5 |
What this means, stated plainly. The compile gate is closed and running. The runtime gate is not being automated: §5.7 keeps its blanket autostart prohibition, and the only mechanisms that would start a PLC unattended either require narrowing that rule (C-1) or a separate toolchain (C-2). Neither is being taken.
The honest consequence is that §5.7’s “green in CI” stays unreachable for every
module type, so conformance claims remain per-release and hand-run rather than
continuous. That is a deliberate position, not an oversight: a §6.2 operator run
produces genuine results, and Read-TcUnitResults.ps1 removes the transcription
step once a PLC is running by any route.
§C and §D below are retained as the record of what was investigated and what the options cost, should the position change. Do not implement them without revisiting the decisions above.
A. Restore the compile gate
Section titled “A. Restore the compile gate”The runner was registered --ephemeral, which accepts exactly one job and then
removes itself. The repository currently reports zero runners, so the next
push has nothing to run on.
A1. Re-register without --ephemeral
Section titled “A1. Re-register without --ephemeral”From the runner directory (currently C:\Projects\Fraktal\actions-runner, which
is inside the working tree — see A3):
.\config.cmd remove --token <REMOVAL_TOKEN>.\config.cmd --url https://github.com/MrFrakt/Fraktal --token <REG_TOKEN> --labels twincat,twincat-test.\run.cmdGet both tokens from Settings → Actions → Runners. Add twincat-test now
even though the TcUnit job stays off — it costs nothing and saves a
re-registration in §D.
self-hosted, Windows and X64 are added automatically; label matching is
case-insensitive, so the workflow’s lowercase windows matches.
A2. Do not install it as a service
Section titled “A2. Do not install it as a service”Invoke-TwinCatBuild.ps1 drives XAE through out-of-process COM
(VisualStudio.DTE.18.0). Under LocalSystem it runs in Session 0 with no user
profile or desktop, where DTE automation is unreliable. Run it interactively. For
unattended operation, autologon a dedicated account and start run.cmd there.
A3. Move the runner out of the working tree
Section titled “A3. Move the runner out of the working tree”It keeps a full second checkout under _work/. .gitignore covers
actions-runner/ so a stray git add -A cannot commit it, but the nested clone
still sits inside the project. Move the folder to C:\actions-runner and re-run
run.cmd from there; it is not a service, so moving the directory is sufficient.
A4. Confirm
Section titled “A4. Confirm”Push anything, or use Actions → CI → Run workflow. Expect
PLC object check (self-hosted TwinCAT) to complete in roughly three minutes
with PLC TcUnit (isolated runtime) skipped.
Exit: two consecutive green object-check runs on main. Met —
0e16d51 and 313c317.
A5. Operating model: on-demand, never left listening
Section titled “A5. Operating model: on-demand, never left listening”The repository is public and the runner reaches a machine with a licensed XAE and a PLC runtime. GitHub advises self-hosted runners only on private repositories. Rather than leave a listener up unattended, the runner stays registered but is started deliberately.
Because a runner with matching labels exists, plc-object-check queues
instead of skipping when nothing is listening — GitHub holds it for roughly 24
hours. ci.yml sets cancel-in-progress: true on a per-ref concurrency group,
so consecutive pushes cancel the older queued run and only the newest survives.
Work therefore accumulates as a single pending compile of the latest commit.
To collect it:
cd C:\Projects\actions-runner./run.cmd # takes the queued job, ~3 minutes# Ctrl+C when it returns to "Listening for Jobs"Do this before a release, and after any change to Fraktal_Core or
Fraktal_Modules — a library change that breaks a consumer is the regression
class this gate exists to catch, and it is the one that actually occurred here on
2026-08-14.
Keep HAS_TWINCAT_RUNNER set to true. Deleting it makes the job skip rather
than queue, which looks tidier but discards the pending-compile behaviour that
makes this model work. The cost of the model is that a run shows in progress
until the runner is started; that is the intended trade, not a fault.
Two standing conditions, since the runner is registered rather than removed:
- Fork-approval must stay at “Require approval for all outside collaborators.”
It is the control that prevents an unapproved fork PR queueing work that would
execute the moment
run.cmdstarts. - The runner lives at
C:\Projects\actions-runner, outside the repository tree. Keep it there; installed in-tree its_work/accumulates a second clone of this repository inside itself.
B. Two decisions that are not engineering
Section titled “B. Two decisions that are not engineering”B1. Licensing — do not mark these checks required yet
Section titled “B1. Licensing — do not mark these checks required yet”The host carries trial licences. Renewal is an interactive captcha, so a required check fails every seventh day, and a required check that fails predictably is one people learn to bypass.
Run the compile job advisory until a permanent licence exists. It already earns its keep: it catches “a library changed and a consumer no longer builds”, which is the exact regression this repository hit locally on 2026-08-16.
Branch protection is the last step of §E, not a step here.
B2. Does §5.7’s autostart prohibition mean what it says?
Section titled “B2. Does §5.7’s autostart prohibition mean what it says?”This decides whether §C is a small change or a project. AGENTS.md §5.7:
Fraktal_TestsandPressTestsrun only on an isolated test runtime/ADS port with Autostart Boot Project disabled; never deploy either as the machine boot application.
The clauses differ in scope. The second names the hazard — a test application auto-starting on equipment. The first is written as a blanket prohibition and is what the gates assert.
It matters because the boot project is the only known way to start a PLC with no person and no IDE prompt, and closing G9 through it costs far less than any alternative. A dedicated CI runtime that controls no I/O is not “the machine”.
Against narrowing it: we already hit the failure mode. A stale
Port_851.autostart marker dated 2026-08-06 survived on the development runtime
and had to be deleted by hand, precisely because boot state outlives the run that
created it.
Decide one:
- Narrow the rule to “never on a runtime with I/O; the gate must clear the
boot project afterwards” → take path C-1. Update AGENTS.md §5.7 and
TWINCAT_XAE_WORKFLOW.md§6.1 together with the code, in the same commit. - Keep it as written → take path C-2.
Do not take C-1 without editing the rule. A gate that violates a documented assertion is worse than either option.
C. Close G9 — start a PLC without a person
Section titled “C. Close G9 — start a PLC without a person”ITcPlcOnline.Login() returns without error, writes nothing to any of the ten
DTE output panes, and leaves IsLoggedIn false with OnlineOperationState 0
indefinitely. Everything up to activation is verified. The eliminated hypotheses
are listed in TWINCAT_XAE_WORKFLOW.md §9.1 — do not re-test them.
Path C-1 — boot project + autostart (requires B2 narrowed)
Section titled “Path C-1 — boot project + autostart (requires B2 narrowed)”C-1.0 — verified 2026-08-16. The premise holds.
Activation writes the boot application, with no login and no download involved.
Measured on the local development runtime: the gate run started 14:33:56, failed
at the login assertion (IsLoggedIn false, OnlineOperationState 0), and
Port_851.app and Port_851_boot.tizip were nevertheless written at
14:34:13–14. Nothing else was driving that runtime.
Invoke-TwinCatTcUnitGate.ps1’s header asserted the opposite — “It never
generates a boot project” — and has been corrected. C-1 is therefore a live
option, gated only on B2.
Repeat the check below on the isolated runtime before relying on it there, since the measurement above is from the development runtime:
On the isolated runtime:
# 1. Note the current boot state$boot = 'C:\ProgramData\Beckhoff\TwinCAT\3.1\Runtimes\<Instance>\3.1\Boot\Plc'Get-ChildItem $boot -Filter 'Port_851.*' | Select-Object Name,Length,LastWriteTime
# 2. Activate through the gate (it will still fail at login - expected).\FraktalCore\PLC\TwinCAT\tools\Invoke-TwinCatTcUnitGate.ps1 ` -Solution FraktalCore\PLC\TwinCAT\Tests\FraktalTests.slnx ` -TargetNetId <ISOLATED_NETID> -ExpectedNetId <ISOLATED_NETID> ` -ExpectedRunner PRG_TcUnitRunner -ExpectedTests 106 -ExpectedSuites 31
# 3. Did Port_851.app and Port_851_boot.tizip update?Get-ChildItem $boot -Filter 'Port_851.*' | Select-Object Name,Length,LastWriteTimeIf their timestamps advanced, activation writes the boot application and the premise holds. If not, C-1 is dead — go to C-2.
C-1.1 Prove it starts unattended
Still by hand, once, before touching the gate:
- In XAE on the isolated target, enable Autostart Boot Project on the PLC project and activate.
- Restart TwinCAT (
TwinCAT → Restart TwinCAT System). - Without logging in, run the reader:
.\FraktalCore\PLC\TwinCAT\tools\Read-TcUnitResults.ps1 ` -NetId <ISOLATED_NETID> -OutputLog artifacts\tcunit\probe.logA summary here means the whole problem is solved: the application ran on its own
and the reader read it. This is also the first end-to-end proof of
Read-TcUnitResults.ps1, which has never read a live run.
C-1.2 Fold it into the gate
Replace the login/start block in Invoke-TwinCatTcUnitGate.ps1 with:
- set
BootProjectAutostarttrue on the PLC project; - activate, restart, wait for
IsTwinCATStarted(); - call
Read-TcUnitResults.ps1; - in
finally: set autostart false, re-activate, and deletePort_851.autostartfrom the runtime’s Boot folder.
Step 4 is not optional and is the whole reason B2 needs deciding rather than assuming. A run that aborts between 1 and 4 leaves a test application armed to start on the next reboot. Assert in step 4 that the marker is gone, and fail the gate if it is not — a cleanup that fails silently recreates the Aug-6 marker problem.
Keep both existing safeguards intact; §9 permits automation only with them:
the -ExpectedNetId refusal, and a hard failure if the target has any I/O
configured.
Path C-1.3 — load the boot project on demand — investigated, does not exist
Section titled “Path C-1.3 — load the boot project on demand — investigated, does not exist”This was proposed as a way to avoid the §5.7 decision entirely: if the runtime
could be told to load a boot project as an action, the gate would get a running
application with no login and no prompt while Autostart stayed disabled. The
premise was PLC_OPSTATE_LOADBOOTPROJECT (8192).
It was a misreading, resolved 2026-08-16. Do not re-open it.
PLC_OPSTATE appears in TCatSysManagerLib only as the return type of
get_OnlineOperationState. It is never a parameter to anything. It is a status
readout: LOADBOOTPROJECT reports that the runtime is loading a boot project,
and cannot be used to ask for one.
A full sweep of the library for members matching Boot / Load / Download / Activate / Restart gives the complete boot surface, and there is no load action in it:
| Member | Effect |
|---|---|
GenerateBootProject(Boolean) |
creates a boot project |
get/set_BootProjectAutostart(Boolean) |
reads/sets the persistent flag |
CreateOfflineBootPrj(String) |
offline creation |
ActivateConfiguration(), StartRestartTwinCAT() |
already called by the gate |
BeforeDownload / AfterDownload |
notification hooks, not commands |
TcXaeMgmt is not installed, and would not change the conclusion: loading an
application requires either a download or a boot-load. There is no third
mechanism.
One useful result. set_BootProjectAutostart(Boolean) is settable at runtime
through automation, so C-1’s transient variant — arm, activate, restart, run,
read, disarm, re-activate within a single run — is mechanically clean and needs no
file manipulation. The implementation is small. What blocks C-1 is therefore
entirely the rule, and always was.
Path C-2 — drive the runtime without the IDE (no rule change)
Section titled “Path C-2 — drive the runtime without the IDE (no rule change)”TcUnit-Runner is the known tool for this. Budget real time: it is a separate toolchain to install, license-check and wire, and it must still satisfy the §9 constraints on target identity and destructive state.
Whichever path is taken, Read-TcUnitResults.ps1 is unaffected — it only needs a
running PLC.
D. Wire the TcUnit job
Section titled “D. Wire the TcUnit job”Only after §C produces a result without a person.
D1. The isolated runtime
Section titled “D1. The isolated runtime”ci.yml requires the hook never target a machine runtime. The committed target
192.168.132.128.1.1 is unreachable; everything to date ran on the development
runtime. Stand that VM up, or designate another runtime that drives no I/O, and
put its NetId in the test wrappers.
D2. The hook
Section titled “D2. The hook”TCUNIT_RUNNER_SCRIPT must point at a runner-local .ps1 — deliberately not in
the repository, because it encodes machine-specific NetId and ports, and because
a repo-resident script that drives a runtime is one a pull request can edit.
Contract, fixed by ci.yml:
& $runner -Gate <CoreModules|Press> -Solution <abs .slnx> -OutputLog <abs path>Exit 0 on success, and write to -OutputLog a file containing exactly one
TcUnit summary. tcunit_to_junit.py then validates it and rejects a log holding
two summaries, so a capture window that catches a green run followed by a red one
cannot be graded green.
A minimal hook is a wrapper: call Invoke-TwinCatTcUnitGate.ps1 with the
runner’s own NetId and the expected counts, and copy its raw log to -OutputLog.
D3. Switch it on
Section titled “D3. Switch it on”Settings → Secrets and variables → Actions → Variables:
HAS_TWINCAT_TEST_RUNTIME = trueTCUNIT_RUNNER_SCRIPT = <absolute runner-local path to the .ps1>The editor hints on ci.yml lines 190 and 196 (“Context access might be
invalid”) are the extension resolving these against variables that do not exist
yet. They disappear on their own here — they are an accurate status indicator,
not a defect.
D4. Evidence
Section titled “D4. Evidence”Per TWINCAT_XAE_WORKFLOW.md §8, retain repository revision,
.plcproj/runner/TMC hashes, XAE/XAR build, platform, target identity and ADS
port, autostart state, runner identity, all five TcUnit summary fields, the raw
log and the generated JUnit. A result without those identities is diagnostic
information, not release evidence.
Note the expected counts are 166 tests / 39 suites (Core+Modules) and
8 / 2 (Press). Derive them from source rather than trusting any table: the
suite count is the runner POU’s VAR block, the test count is the TEST('…')
calls in the suites it instantiates. A suite that exists but is not instantiated
does not run, and would make the log self-consistent while silently under-testing.
E. Exit criteria
Section titled “E. Exit criteria”Phase 2 as originally scoped is finished when all of these hold:
PLC object checkgreen onmainfrom a clean clone, on a runner that survives more than one job. — met (0e16d51,313c317,e9af27f).PLC TcUnitgreen on an isolated runtime, started and read without a person, reporting 106/31 and 8/2 with matching runner identities. — not pursued, per the decisions above.- JUnit and log hashes archived under
Specification/Evidence/. — follows 2. - Both checks required on
main. — out of scope while licences are trial.
Only item 1 is being pursued, and it is done. Recording the rest as not pursued rather than pending is the point: an exit criterion nobody intends to meet is not a plan, and a status page that lists it as outstanding work misrepresents where the project actually stands.
What replaces item 2 in practice: run the §6.2 operator procedure when a runtime
result is wanted — before a release, or after a change to a reusable type — and
read the outcome with Read-TcUnitResults.ps1 rather than transcribing the log
window. Retain the §8 evidence set for any run that is meant to support a claim.
F. The manual runtime run
Section titled “F. The manual runtime run”Proven 2026-08-16 and recorded in
Specification/Evidence/2026-08-17_Core_Modules_TcUnit.md. This is now the only
thing standing between a change and a regression, because CI compiles but does
not execute. Ten module types ship with suites today and nothing forces them to
run; treat this as a discipline, not a convenience.
F1. When to run it
Section titled “F1. When to run it”- before a release;
- after any change to
Fraktal_CoreorFraktal_Modules; - after adding a module type — which is every step of phase 4.
F2. How
Section titled “F2. How”- Open the gate solution in XAE, select the local target, Activate Configuration, then PLC → Login → Yes → Start (§6.2).
- While it is still running, read the result:
.\FraktalCore\PLC\TwinCAT\tools\Read-TcUnitResults.ps1 ` -NetId <TARGET_NETID> -OutputLog artifacts\tcunit\manual.log
python FraktalCore\PLC\TwinCAT\tools\tcunit_to_junit.py ` artifacts\tcunit\manual.log artifacts\tcunit\manual.junit.xml ` --gate-name CoreModules --expected-tests <N> --expected-suites <M> ` --expected-runner PRG_TcUnitRunner- For a run meant to support a claim, copy both files into
Specification/Evidence/under a dated name and write the record with the §8 identity set.2026-08-17_Core_Modules_TcUnit.mdis the template.
Invoke-TwinCatTcUnitGate.ps1 -Interactive automates steps 1 and 2 apart from the
download prompt, which it puts on the operator’s desktop. Useful, but it is not
the documented path and it activates — read §6.1 before pointing it anywhere.
F3. The counts are pinned in three places
Section titled “F3. The counts are pinned in three places”ci.yml, guide §6.3, and every evidence record. Every new module type changes
all three. Derive them from source rather than trusting any table: the suite
count is the runner POU’s VAR block, the test count is the TEST('…') calls in
the suites it instantiates. A suite that exists but is not instantiated does not
run, and would leave the log’s own totals self-consistent while silently
under-testing.
Current: 166 tests / 39 suites (Core+Modules), 8 / 2 (Press).
F4. Housekeeping that bites
Section titled “F4. Housekeeping that bites”XAE strips BootProjectAutostart="false" and TargetNetId from the .tsproj
whenever it opens or activates the solution. Both gates snapshot and restore
them, but an abort between snapshot and restore leaves the stripped file in the
tree — this happened three times on 2026-08-16. Check git status after a
manual session, and git checkout -- the wrapper if it shows modified.
Built from Specification/Guides/CI_RUNTIME_GATE_RUNBOOK.md at revision a1163c7 of the Fraktal repository.